Passa al contenuto principale Salta alla ricerca Passa alla navigazione principale

Advanced Chemistry with Vernier - Print and E-Book

Info sui prodotti "Advanced Chemistry with Vernier - Print and E-Book"

Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor.

​Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments.

Use it in addition to​ ​Vernier Chemistry Investigations for Use with AP Chemistry​ (APCHEM) ​for a comprehensive set of topics.​

Bildungsstufe: Scuola media, Scuole medie superiori e professionali, Secundario II
Fach: chimica
Hersteller: Vernier
lingua: inglese

0 di 0 valutazioni

Valutazione media di 0 su 5 stelle

Formula una valutazione!

Condividi le tue esperienze con il prodotto con altri clienti.


Salta la galleria dei prodotti

Accessory Items

Go Direct™ pH Sensor
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. The Go Direct pH Sensor is an important and versatile sensor for lab and field activities alike. It gives students the freedom to explore pH without the inconvenience of wires—no more spilled solutions or dangling wires. The Go Direct pH transmits live readings and captures data in real-time. The Go Direct pH Sensor can be used in a variety of experiments: Conduct acid-base titrations. Monitor pH change during chemical reactions. Test the pH and alkalinity of bodies of water. Investigate household acids and bases. This sensor is comprised of a pH electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. Specification: pH range: 0–14 Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Shaft diameter: 12 mm OD Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Connections: Wireless: Bluetooth Wired: USB Included: Go Direct pH (includes Go Direct Electrode Amplifier) Micro USB Cable Quick-start guide 

CHF 242.60*
Go Direct™ Conductivity Probe
The Go Direct Conductivity Probe determines the ionic content of an aqueous solution by measuring its electrical conductivity. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Go Direct Conductivity Probe determines the ionic content of an aqueous solution by measuring its electrical conductivity. It features a built-in temperature sensor to simultaneously read conductivity and temperature. Automatic temperature compensation allows students to calibrate the probe in the lab and then make measurements outdoors without temperature changes affecting data. This temperature compensation can be turned off to perform conductivity studies as a function of temperature. The Go Direct Conductivity Probe has a range of 0 to 20,000 μS/cm to provide optimal precision in any given range. An alternating current at its electrodes prevents polarization and electrolysis, reducing contamination of solutions. Its ABS-body graphite electrode resists the corrosion typical in metal electrodes. The Go Direct Conductivity Probe can be used in a variety of experiments: Demonstrate diffusion of ions through membranes. Investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions. Measure Total Dissolved Solids (TDS). Specifications: Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS) Temperature compensation: Automatic from 5 to 35°C, can be turned off Temperature range (can be placed in): 0 to 80°C Cell constant: 1.0 cm-1 Description: ABS body, parallel carbon (graphite) electrodes Dimensions: 12 mm OD and 120 mm length Connections: Wireless: Bluetooth Wired: USB Included Go Direct Conductivity Probe Micro USB Cable

CHF 295.60*
Go Direct™ Drop Counter
The Go Direct Drop Counter precisely records the number of drops of titrant added during a titration and then automatically converts it to volume. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Conducting a titration has never been easier. Use Go Direct Drop Counter in conjunction with our other Go Direct sensors, such as Go Direct pH, Go Direct Conductivity, or Go Direct ORP, to perform acid-base, conductometric, or potentiometric titrations. Designed with a wide drop-detecting area, Go Direct Drop Counter removes the need for precise burette alignment. We’ve also included a large sensor slot for conventional stick-style sensors and a smaller, adjustable slot for temperature probes. The adjustable clamp easily fits our Stir Station and most laboratory ring stands and lattices. Specifications: Accurate drop counting at rates up to 6 drops/s Dimensions: Opening for drops: 3 cm Openings for sensors (diameter): 7 mm and 13 mm Ring stand opening: 16 mm Total length: 15.5 cm, width: 4.5 cm, height: 1.8 cm Distance from center of ring stand opening to center of drop opening (ideal): 10.5 cm Distance from center of ring stand opening to center of sensor opening (ideal): 12 cm Connections: Wireless: Bluetooth Wired: USB Included Go Direct Drop Counter Plastic reagent reservoir Plastic valve with a double stopcock fitting Vernier Microstirrer Micro USB Cable

CHF 262.90*
Precision Volume Dispenser
Il dosatore volumetrico di precisione offre un dosaggio altamente accurato e controllato delle gocce per titolazioni automatizzate. Se abbinato a un contagocce, migliora l'efficienza e la precisione, fornendo risultati costanti con errori ridotti rispetto ai metodi manuali. Ciò lo rende ideale per semplificare gli esperimenti di titolazione.

CHF 201.80*
Go Direct™ Colorimeter
The 4-wavelength Go Direct Colorimeter measures absorbance or transmittance of a liquid sample. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Use this sensor to explore absorbance and percent transmittance in a variety of experiments including Beer’s law (absorbance vs. concentration) and kinetic studies (concentration vs. time). Students select between four wavelengths (430 nm, 470 nm, 565 nm, 635 nm) to set up their experiment. Go Direct Colorimeter features one-step calibration for all four wavelengths. It’s as simple as inserting a cuvette of distilled water and pressing the Calibrate button. Go Direct Colorimeter can be used in a variety of experiments: Conduct Beer’s law investigations. Determine the concentration of unknown solutions. Study changes in concentration vs. time. Monitor reaction rates. Specifications Range: 0 to 3 (absorbance) Useful range: 0.05 to 1.0 (absorbance) 90% to 10% transmittance (%T) Wavelengths: 430 nm, 470 nm, 565 nm, 635 nm Connections: Wireless: Bluetooth Wired: USB Included: Go Direct Colorimeter Micro USB Cable 3.5 mL cuvettes (15)

CHF 303.70*
Go Direct™ Gas Pressure Sensor
The Go Direct Gas Pressure Sensor measures the absolute pressure of a gas. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Use Go Direct Gas Pressure Sensor to monitor gas pressure in a variety of experiments. It records accurate absolute pressure readings relative to the perfect vacuum reference point inside the sensor, allowing you to go below atmospheric pressure or up to 400 kPa. Easily change the displayed units to any one of seven options (kPa, mmHg, inHg, mbar, psi, atm, torr). Includes a syringe, tubing, and stoppers to ease setup for experiments such as Boyle’s law. The Go Direct Gas Pressure Sensor can be used in a variety of experiments: Investigate Boyle’s law and Charles’ law. Investigate grip strength and muscle fatigue (using Gas Pressure Bulb, not included). Measure the production of oxygen gas produced when hydrogen peroxide is destroyed by the enzyme catalase. Monitor plant transpiration. Specifications: Range: 0 to 400 kPa Resolution: 0.03 kPa Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa Connections: Wireless: Bluetooth Wired: USB Included: Vernier Go Direct Gas Pressure Sensor Tapered valve connectors (2) inserted into a No. 5 stopper Tapered valve connector (1) inserted into a No. 1 stopper Two-way valve 18 inch Tygon tubing with Luer Lock connectors 20 mL syringe White transpiration tubing clamps (2)

CHF 242.60*
Go Direct® Current Probe
Description Simplify your experimental setup with the Go Direct Current Probe. It connects wirelessly via Bluetooth® or wired via USB to your device. The wireless connection eliminates additional cables that can clutter the lab bench. Capture small currents like those produced by a magnet falling through a coil. Use in combination with the Go Direct Voltage Probe to investigate Ohm’s law or series and parallel circuits. Explore RC and RLC circuits. Rechargeable Battery—Ready When You Are The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 2 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students. Wired or Wireless—The Flexibility to Choose Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.   Specifications Range: +/- 1 A and +/- 0.1 A Maximum non-damaging current: 1.5 A and 0.5 A Typical resolution: 0.031 mA and 0.003 mA Connections: Wireless: Bluetooth Wired: USB

CHF 222.20*
Go Direct™ ORP Sensor
The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Use the Go Direct ORP Sensor to measure the ability of a solution to act as an oxidizing agent and to quantify ion activity. This sensor measures the capacity of a solution to either release or accept electrons from chemical reactions. This sensor is comprised of an ORP electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. The Go Direct ORP Sensor can be used in a variety of experiments: Determine the equivalence point of an oxidation-reduction titration. Measure the oxidizing ability of chlorine in swimming pools. Investigate the ORP of drinking water. Specifications: ORP Electrode Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Temperature range: 0 to 60°C 12 mm OD Impedance: ~20 kΩ at 25ºC Electrode Amplifier Units: mV Input range: ±1000 mV Connections: Wireless: Bluetooth Wired: USB Included: Go Direct ORP (includes Go Direct Electrode Amplifier) Micro USB Cable

CHF 283.30*
Go Direct™ Radiation Monitor
Go Direct Radiation Monitor rileva le radiazioni alfa, beta, gamma e raggi X. Si collega direttamente alla piattaforma in modalità wireless tramite Bluetooth® o cablato via USB. Utilizza il Go Direct Radiation Monitor per analizzare le statistiche delle radiazioni, misurare la velocità di decadimento nucleare e monitorare la progenie del radon. Questo sensore di facile utilizzo è costituito da un tubo Geiger-Mueller montato in una piccola e robusta custodia di plastica. Una sottile finestra protetta da uno schermo metallico consente di rilevare le radiazioni alfa, beta e gamma. Ogni nuovo rilevamento è segnalato da un indicatore LED rosso lampeggiante e può anche essere accompagnato da un segnale audio opzionale. Il Go Direct Radiation Monitor può essere utilizzato in una varietà di esperimenti: Determinare il tempo di dimezzamento di un isotopo. Indagare sulla schermatura contro le radiazioni. Rilevare le sorgenti di radiazioni di fondo. Specifiche: Sensore: tubo GM temprato alogeno LND 712 (o equivalente) con finestra terminale mica, spessore da 1,5 a 2,0 mg/cm2 Sensibile alle radiazioni alfa, beta, gamma e raggi X Alimentato da batteria ricaricabile da 300 mAh, ricaricabile tramite cavo USB LED rosso lampeggia sul rilevamento di radiazioni Segnale audio opzionale sul rilevamento delle radiazioni Collegamenti: Wireless: Bluetooth Cablato: USB Inclusi: Vai Monitor diretto delle radiazioni Cavo micro USB

CHF 507.60*
Go Direct™ Temperature Sensor
La sonda di temperatura Go Direct è un robusto sensore di temperatura per uso generale che gli studenti possono utilizzare per monitorare la temperatura. Si collega direttamente alla piattaforma in modalità wireless tramite Bluetooth® o via cavo tramite USB. La sonda di temperatura Go Direct, robusta e multiuso, offre agli studenti il vantaggio della connettività ovunque e ovunque si lavori. Essendo anche impermeabile, Go Direct Temperature è più durevole dei sensori che sono semplicemente resistenti all'acqua. A differenza di un termometro tradizionale, Go Direct Temperature consente agli studenti di raccogliere misure di temperatura in tempo reale di un singolo caso o di un periodo di tempo. L'intervallo di temperatura e la funzionalità wireless rendono Go Direct Temperature il sensore ideale per le applicazioni reali. La sonda Go Direct Temperature può essere utilizzata in una varietà di esperimenti: Condurre reazioni endotermiche ed esotermiche. Studiare il congelamento e la fusione dell'acqua. Misurare il contenuto energetico degli alimenti. Esaminare l'assorbimento dell'energia radiante. Monitorare le condizioni ambientali. Specifiche tecniche: Intervallo di temperatura: da -40 a 125°C Intervallo di temperatura di manipolazione: da -10 a 45°C Precisione: ±0,25°C Tempo di risposta (tempo per il 90% della lettura): 20 secondi (in acqua, con agitazione) Connessioni: Senza fili: Bluetooth Con cavo: USB Incluso: Sensore di temperatura Go Direct Cavo micro USB Guida rapida

CHF 161.00*
Salta la galleria dei prodotti

Similar Items

Investigating Chemistry through Inquiry
The Investigating Chemistry through Inquiry lab book contains 25 inquiry-based chemistry investigations. The book is authored by two long-time chemistry teachers, Donald L. Volz and Ray Smola, who have enjoyed using the inquiry method in their own instruction. Each experiment includes a preliminary activity, teacher information, sample researchable questions, and sample data for those researchable questions. If you are new to inquiry-based instruction, the extensive Instructor Sections that are included with each investigation will help guide you through the inquiry-based style of chemistry instruction. Included with Investigating Chemistry through Inquiry  Electronic Version 25 inquiry-based, chemistry investigations Access to up-to-date versions of the experiments Essential teacher information for successful inquiry investigations Suggested researchable questions, sample data, and graphs A generous site license—buy one book and duplicate the labs for your class Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

Da CHF 83.40*
Chemistry with Vernier
Chemistry with Vernier is the foundational chemistry book for high school and college courses. Chemistry with Vernier has more than 36 experiments in thermochemistry, gas laws, acid-base reactions, equilibrium, electrochemistry, electrolytes, states of matter, and more. Experiments are included for the Gas Pressure Sensor, Temperature Probe, pH Sensor, Conductivity Probe, Colorimeter, and Voltage Probe. If you teach Advanced Placement (AP), International Baccalaureate (IB), or college chemistry, you should also consider Advanced Chemistry with Vernier (CHEM-A) and Investigating Chemistry through Inquiry (CHEM-I).

Da CHF 83.40*
Forensic Chemistry Experiments
Each of the 15 experiments in this book kicks off with a case study designed to engage high-school and college-level chemistry students. Immerse them in the excitement of solving crimes through hands-on experimentation using Vernier sensors such as pH, pressure, conductivity, and temperature to investigate complex questions involving forensics. Students explore gas pressure through a failed bottle rocket launch, Beer’s law through a case of poisoned wine, and even more through engaging forensics investigations. Electronic Version 14 ready-to-use student experiments Electronic access to up-to-date versions of the experiments Instructions for data collection with Vernier Graphical Analysis app with Go Direct sensors. (Does not support data collection with Logger Pro or LabQuest App) Essential instructor information, including teaching tips, suggested answers, and sample data and graphs Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Complete equipment and supplies list A generous site license­—buy one book and duplicate the experiments for your class Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

Da CHF 64.80*