Passa al contenuto principale Salta alla ricerca Passa alla navigazione principale

ISE Ammonium High Standard

Info sui prodotti "ISE Ammonium High Standard"

The Low ISE standard is used to calibrate our Ammonium Ion-Selective Electrode. This solution has a concentration of 100 mg/L.

Hersteller: Vernier

0 di 0 valutazioni

Valutazione media di 0 su 5 stelle

Formula una valutazione!

Condividi le tue esperienze con il prodotto con altri clienti.


Salta la galleria dei prodotti

Accessory Items

Go Direct® Ammonium Ion-Selective Electrode
Dieser Go Direct Sensor mit ionenselektiver Elektrode für Ammonium (NH4) eignet sich zur Messung des Potentials (mV) und zur Berechnung der Konzentration von NH4-Ionen in wässrigen Lösungen. Die Verbindung kann kabellos über Bluetooth® oder kabelgebunden mit USB an Interface, PC, Tablet, Smartphone oder Chromebook erfolgen. Messbereich (mV): ±1000 mV Messbereich (Konzentration): 1 bis 18.000 mg/L (oder ppm) Genauigkeit: ±10% des Messbereichs (kalibriert 1 bis 100 mg/L) Querempfindlichkeiten: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+ pH-Bereich: 2-7 (keine pH-Kompensation) Temperaturbereich: 0-40°C (keine Temperaturkompensation) Elektrodensteigung: 55 ±3 mV/Dekade bei 25°C Elektrodenwiderstand: 0,1 bis 5 MΩ Minimaler Probenumfang: muss 2,8 cm eingetaucht werden. Konnektivität: Bluetooth, USB

CHF 670.70*
Ammonium Ion-Selective Electrode
Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+. The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf. Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.     Specifications: User manual

CHF 672.70*
Salta la galleria dei prodotti

Similar Items

ISE Ammonium Replacement Module
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of an Ammonium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use.

CHF 193.20*
ISE Chloride High Standard
The High ISE standard is used to calibrate our Chloride Ion-Selective Electrode. This solution has a concentration of 1000 mg/L Cl-.

CHF 59.10*
Soluzione standard di potassio
Gli standard ISE basso e alto vengono utilizzati per calibrare i nostri elettrodi selettivi agli ioni di potassio. Bassa concentrazione: questa soluzione da 500 mL ha una concentrazione di 10 mg/L ed è utilizzabile con ISE di potassio. Alta concentrazione: questa soluzione da 500 mL ha una concentrazione di 1000 mg/L ed è utilizzabile con ISE di potassio.

CHF 59.10*
ISE Ammonium Low Standard
The Low ISE standard is used to calibrate our Ammonium Ion-Selective Electrode. This solution has a concentration of 1 mg/L.

CHF 59.10*
ISE Calcium High Standard
The High ISE standard is used to calibrate our Calcium Ion-Selective Electrode. This solution has a concentration of 1000 mg/L.

CHF 59.10*
ISE Nitrate High Standard
  The High ISE standard is used to calibrate our Nitrate Ion-Selective Electrode. This solution has a concentration of 100 mg/L.

CHF 59.10*