Passer au contenu principal Passer à la recherche Passer à la navigation principale

Ammonium Ion-Selective Electrode

Informations sur le produit "Ammonium Ion-Selective Electrode"

Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+.

The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.

Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.

Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.

 

 

Specifications: User manual

Bildungsstufe: Sec. II & tertiaire
Fach: biologie, chimie

0 sur 0 évaluations

Note moyenne de 0 sur 5 étoiles

Laissez une évaluation !

Partagez avec d'autres clients votre avis sur le produit.


Ignorer la galerie de produits

Accessory Items

Electrode Support
The Vernier Electrode Support connects to all standard ring-stand posts to keep sensors firmly in place during an experiment. The Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. The clamp end makes connecting to ring stands easy, accommodating post diameters between ~0.5 and 1 cm. The grooves on the Electrode Support to hold the wire leads for electroplating or electrolysis experiments.

20.30 CHF*
ISE Ammonium Low Standard
The Low ISE standard is used to calibrate our Ammonium Ion-Selective Electrode. This solution has a concentration of 1 mg/L.

59.10 CHF*
Water Quality with Vernier
Water Quality with Vernier has 18 water quality tests, including pH, total dissolved solids, dissolved oxygen, BOD, flow rate, turbidity, nitrates, and phosphates. All nine tests in the Water Quality Index (WQI) are supported. A comprehensive introduction is included for each test, providing important background information for the students. The printed version includes access to the electronic edition online.  

De 83.40 CHF*
ISE Ammonium High Standard
The Low ISE standard is used to calibrate our Ammonium Ion-Selective Electrode. This solution has a concentration of 100 mg/L.

59.10 CHF*
ISE Ammonium Replacement Module
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of an Ammonium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use.

193.20 CHF*
Ignorer la galerie de produits

Similar Items

Calcium Ion-Selective Electrode
Data from the Calcium ISE can give a good indication of hardness of water (as Ca2+). The concentration of Calcium is also used as an endpoint indicator in EDTA-Ca/Mg hardwater titrations. The Calcium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   CA-BTA User manual

713.50 CHF*
Go Direct® Ammonium Ion-Selective Electrode
Dieser Go Direct Sensor mit ionenselektiver Elektrode für Ammonium (NH4) eignet sich zur Messung des Potentials (mV) und zur Berechnung der Konzentration von NH4-Ionen in wässrigen Lösungen. Die Verbindung kann kabellos über Bluetooth® oder kabelgebunden mit USB an Interface, PC, Tablet, Smartphone oder Chromebook erfolgen. Messbereich (mV): ±1000 mV Messbereich (Konzentration): 1 bis 18.000 mg/L (oder ppm) Genauigkeit: ±10% des Messbereichs (kalibriert 1 bis 100 mg/L) Querempfindlichkeiten: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+ pH-Bereich: 2-7 (keine pH-Kompensation) Temperaturbereich: 0-40°C (keine Temperaturkompensation) Elektrodensteigung: 55 ±3 mV/Dekade bei 25°C Elektrodenwiderstand: 0,1 bis 5 MΩ Minimaler Probenumfang: muss 2,8 cm eingetaucht werden. Konnektivität: Bluetooth, USB

670.70 CHF*
Nitrate Ion-Selective Electrode
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample. The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   NO3-BTA User manual

548.40 CHF*