Passer au contenu principal Passer à la recherche Passer à la navigation principale

Electrode Support

Informations sur le produit "Electrode Support"

The Vernier Electrode Support connects to all standard ring-stand posts to keep sensors firmly in place during an experiment.

The Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place.

The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors.

The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp.

The clamp end makes connecting to ring stands easy, accommodating post diameters between ~0.5 and 1 cm. The grooves on the Electrode Support to hold the wire leads for electroplating or electrolysis experiments.

0 sur 0 évaluations

Note moyenne de 0 sur 5 étoiles

Laissez une évaluation !

Partagez avec d'autres clients votre avis sur le produit.


Ignorer la galerie de produits

Accessory Items

ORP Sensor
The Oxidation-Reduction Potential (ORP) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. Use the ORP Sensor to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction. Type:Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution:pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Redox potential range:-450 to +1100 mV User manual

285.40 CHF*
Go Direct® Électrode sélective pour ions potassium
Utilisez l'électrode sélective d'ions potassium Go Direct pour mesurer sans fil les niveaux d'ions potassium. Le connecteur BNC polyvalent permet aux étudiants de remplacer facilement l'électrode lorsqu'elle expire ou est endommagée. Vous n'avez qu'à remplacer l'électrode et non le capteur entier, ce qui réduit vos coûts d'équipement. L'électrode sélective pour ions potassium Go Direct est dotée d'une électrode de type combiné, non rechargeable et remplie de gel. Comme toutes les autres membranes ISE en PVC, la membrane de l'ISE a une durée de vie limitée. Cependant, le module remplaçable de l'ISE vous permet de vous débarrasser du module de membrane usagé et de le remplacer par un nouveau module.

703.30 CHF*
Microstirrer
When Vernier introduced the new Drop Counter, they decided to include a Vernier Microstirrer to enhance stirring. Since then, they've had many requests to have this as a separate product. The Microstirrer takes the place of the stirring bar that is typically used with a laboratory magnetic stirrer. The new Vernier Microstirrer easily attaches to the end of a pH Sensor, Conductivity Probe, Dissolved Oxygen Probe or Ion-Selective Electrode. When the magnetic stirrer plate (required, but not included) is turned on, its magnetic field turns the paddle wheel of the Microstirrer, resulting in enhanced stirring near the electrode tip. The Microstirrer works with any magnetic stirrer.

18.30 CHF*
Chloride Ion-Selective Electrode
The concentration of the Chloride ion gives a quick measurement of salinity of water samples. Use the Chloride ISE to measure chloride levels in ocean saltwater or salt in food samples. The Chloride ISE has a combination-style, non-refillable, gel-filled electrode. Unlike other ISEs available from Vernier, the Chloride ISE has a solid-state membrane that does not need to be replaced.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   CL-BTA User manual

672.70 CHF*
Nitrate Ion-Selective Electrode
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample. The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   NO3-BTA User manual

713.50 CHF*
Potassium Ion-Selective Electrode
The Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions. The Potassium Ion-Selective Electrode makes the measure of potassium ions portable. When used with a Vernier LabQuest 2, the Potassium ISE can be used to take readings in the field – at lakes or streams. This sensor is easier to set up and use than other methods of measuring potassium ion concentration in aqueous solutions. Because it is a stick-style sensor, its use is similar to using a conductivity probe or a pH sensor in a laboratory setting or in the field. Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results. They are not recommended for middle school or elementary students. User manual

705.30 CHF*
EasyTemp
The Vernier EasyTemp is a rugged, general-purpose temperature sensor for TI graphing handhelds. Vernier EasyTemp has a mini-A USB connector that allows you to attach the temperature probe directly to the USB port of a TI-84 Plus graphing calculator or TI-Nspire handheld. Connecting the sensor to the calculator or handheld will automatically launch the data collection application, and you are ready to collect data. Temperature range:–20 to 115°C Maximum temperature that the sensor can tolerate without damage:150°C Resolution:0.07°C Accuracy:±0.5°C Response time:4 s (to 90% of full reading in water) User manual

112.10 CHF*
Go Direct™ Electrode Amplifier
The Go Direct Electrode Amplifier offers an affordable way to expand your experiment options. Its BNC connector provides the flexibility to attach and remove a Vernier electrode, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. You can explore pH one day and potassium concentrations the next.   Because the Go Direct Electrode Amplifier is compatible with third-party electrodes, students learn consistent calibration and handling techniques on one amplifier using one software program. When electrodes expire or become damaged you need only replace the electrode—lowering your overall equipment costs.   Rechargeable Battery—Ready When You Are The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 2 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.   Wired or Wireless—The Flexibility to Choose Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory. Specifications Units: pH or mV Input range (mV): ±1000 mV Input range (pH): 0 to 14 pH Accuracy with new electrode (mV): ±20 mV Accuracy with new electrode (pH): ±0.2 Connections: Wireless: Bluetooth Wired: USB

181.40 CHF*
Conductivity Probe
The Conductivity Probe determines the ionic content of an aqueous solution by measuring its conductivity. The Conductivity Probe has three ranges, providing optimal precision in any given range. Biology teachers can use this probe to demonstrate diffusion of ions through membranes. Chemistry students are able to quickly investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions. Environmental science students use it to measure TDS, total dissolved solids. Range: Low Range: 0 to 200 μS/cm (0 to 100 mg/L TDS) Mid Range: 0 to 2000 μS/cm (0 to 1000 mg/L TDS) High Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS) Typical Resolution: Low Range: 0.1 μS/cm (0.05 mg/L TDS) Mid Range: 1 μS/cm (0.5 mg/L TDS) High Range 10 μS/cm (5 mg/L TDS) Accuracy using factory calibration: ±8% of full-scale reading for low range ±3% of full-scale reading for mid range ±4% of full-scale reading for high range Accuracy using custom calibration: ±2% of full-scale reading for each range Response Time: 98% of full-scale reading in 5 seconds, 100% of full-scale in 15 seconds Temperature Compensation: automatic from 5 to 35 °C Temperature Range (can be placed in): 0 to 80 °C Cell Constant: 1.0 cm-1   Description: ABS body, parallel carbon (graphite) electrodes Dimensions: 12 mm OD and 150 mm length CON-BTA User manual

297.60 CHF*
Go Direct™ pH Sensor
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. The Go Direct pH Sensor is an important and versatile sensor for lab and field activities alike. It gives students the freedom to explore pH without the inconvenience of wires—no more spilled solutions or dangling wires. The Go Direct pH transmits live readings and captures data in real-time. The Go Direct pH Sensor can be used in a variety of experiments: Conduct acid-base titrations. Monitor pH change during chemical reactions. Test the pH and alkalinity of bodies of water. Investigate household acids and bases. This sensor is comprised of a pH electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. Specification: pH range: 0–14 Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Shaft diameter: 12 mm OD Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Connections: Wireless: Bluetooth Wired: USB Included: Go Direct pH (includes Go Direct Electrode Amplifier) Micro USB Cable Quick-start guide 

242.60 CHF*
PH-METRE PLAT (FPH)
Ce capteur utilise une électrode double jonction ce qui rend possible les mesures avec des tampons Tris, et des solutions contenant des protéines ou des sulfures. Les bas de l'électrode est plat, ce qui facilite les mesures de pH de divers aliments ou du sol. Il possède de la mémoire pour stocker des étalonnages qui seront automatiquement utilisés par le logiciel. Cela permet d'utiliser un étalonnage propre à chaque capteur sans avoir besoin de réétalonner à chaque utilisation. Electrode AG-AgCl gel double jonction Mesure des pH de 0 à 14 Temps de réponse : 98% de la valeur finale en 30 secondes à 25°C Membrane plate en verre Fonctionne de 0 à 100°C Résolution avec CBL/CBL2: 0,03 unités pH Résolution avec LabPro Labquest: 0,008 unités pH Mémoire pour stocker les étalonnages

366.90 CHF*
Go Direct® Ethanol Vapor Sensor
Go Direct Ethanol Vapor measures the concentration of ethanol in the air above an aqueous sample. This sensor can be used in a wide variety of experiments in biological, agricultural, food, and environmental studies. Go Direct Ethanol Vapor can be used in a variety of experiments: Determine the rate of ethanol production during fermentation. Measure the discrete amount of ethanol in a given sample. Investigate which sugars yeast can ferment. Identify specific organisms that can utilize ethanol fermentation as a metabolic pathway. Rechargeable Battery—Ready When You AreThe robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 2 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students. Wired or Wireless—The Flexibility to ChooseOur Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.

385.30 CHF*
Capteur de Temperature
Ce capteur de température est formé d’une tige en acier inoxydable qui peut être trempée dans des liquides organiques, des solutions acides ou basiques. Il est formé d’une thermistance et peut mesurer des températures de -40°C à 135°C Gamme de mesures :-40°C à 135°C Précision : ± 0,2°C à 0°C, ± 0,5°C à 100°C Temps de réponse : 90% de la valeur en 10s dans l'eau, en 90s dans l'air agité, en 400s dans l'air calme Résolution avec LabPro, LabQuest : 0.17°C(-40°C à 0°C) 0.03°C(0°C à 40°C) 0.1°C(40°C à 100°C) 0.25°C(100°C à 125°C) Température maximale supportable : 150°C Garantie 5 ans User manual

87.60 CHF*
Stir Station
La Stir Station est une combinaison d'agitateur magnétique et d'un support annulaire. Le poste d'agitation manipule efficacement des béchers et d'autres contenants aussi petits que 50 mL et aussi grands qu'un litre (capacité pratique de 800 mL). Il fonctionne efficacement avec des béchers dotés d'un large éventail de tailles et de formes de barres d'agitation magnétiques. Utilise un contrôle de vitesse en boucle fermée, ce qui facilite l'ajustement de sa vitesse d'agitation (50–1250 tr/min).La plate-forme d'agitation est éclairée par trois DEL blanches fraîches. Les DEL sont placées sous la plate-forme d'agitation pour fournir un excellent éclairage d'un récipient en verre contenant du liquide.Comprend un poteau annulaire amovible de 18" idéalement positionné et fixé à la base de l'agitateur, à une distance qui s'accommode facilement de la plupart des pinces buret ou utilitaires.Fonctionne avec alimentation CA (adaptateur inclus) ou quatre piles C (non incluses).Suffisamment robuste pour faire fonctionner la plupart des barres magnétiques de taille courante ou un Microstirrer Vernier.Possède une plaque d'agitation en plastique résistant aux produits chimiques. Comprend: Station de remorquage de Vernier Vernier Microstirrer Barre d'agitation (4 cm) Adaptateur de courant continu 6 volts Poteau annulaire (46 cm) Manuel d'utilisation

375.10 CHF*
Calcium Ion-Selective Electrode
Data from the Calcium ISE can give a good indication of hardness of water (as Ca2+). The concentration of Calcium is also used as an endpoint indicator in EDTA-Ca/Mg hardwater titrations. The Calcium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   CA-BTA User manual

713.50 CHF*
Constant Current System
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments. The Constant Current System eliminates the need for a separate power supply when performing electroplating and electrolysis experiments in chemistry. It is capable of delivering up to 0.6 A at 5 V DC. A current-sensing resistor allows monitoring of the output current through the sensor cable. The user can set the current by tuning the dial with the system automatically adjusting the voltage. Use the Constant Current System to explore Faraday’s law and determine Avogadro’s Number. Note that it can only be used in conjunction with its own built-in power supply—it cannot be used to measure the current of a circuit using a different power supply. User Manual

234.40 CHF*
Go!Temp - Single Sensor
Collect temperature data directly through the USB port of a computer. We’ve made it easy to use technology to teach science concepts with Go!Temp. Plug Go!Temp directly into your computer or Chromebook USB port to start collecting real-time temperature data. Range:-20°C – 115°C Maximum temperature that the sensor can tolerate without damage:150°C Resolution:0.07°C Accuracy:± 0.5°C Response Time:4s (to 90% of full reading in water) User manual

112.10 CHF*
Go Direct™ Constant Current System
Le système à courant constant Go Direct est une source d'alimentation en courant continu dotée d'une sonde de courant intégrée conçue pour les expériences en électrochimie. Il se connecte directement à votre plate-forme sans fil via Bluetooth® ou câblé via USB. Utilisez le système Go Direct à courant constant pour déterminer le nombre d'Avogadro et effectuer diverses expériences de galvanoplastie et d'électrolyse. Ce système combine une source d'alimentation en courant continu et un capteur de courant intégré pour éliminer la nécessité d'une alimentation séparée, et il peut fournir jusqu'à 0,6 A à 5 V en courant continu. Les réglages de tension sont automatiquement ajustés pour compléter le réglage de courant choisi. Spécifications: Gamme: 0 à 0,6 A Tension d'alimentation: 5 VDC Connexions: Sans fil: Bluetooth Câblé: USB Comprend: Vernier Go Direct Système à courant constant Alimentation électrique Micro USB Câble

234.40 CHF*
Ammonium Ion-Selective Electrode
Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+. The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf. Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.     Specifications: User manual

672.70 CHF*
Go Direct™ ORP Sensor
The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Use the Go Direct ORP Sensor to measure the ability of a solution to act as an oxidizing agent and to quantify ion activity. This sensor measures the capacity of a solution to either release or accept electrons from chemical reactions. This sensor is comprised of an ORP electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. The Go Direct ORP Sensor can be used in a variety of experiments: Determine the equivalence point of an oxidation-reduction titration. Measure the oxidizing ability of chlorine in swimming pools. Investigate the ORP of drinking water. Specifications: ORP Electrode Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Temperature range: 0 to 60°C 12 mm OD Impedance: ~20 kΩ at 25ºC Electrode Amplifier Units: mV Input range: ±1000 mV Connections: Wireless: Bluetooth Wired: USB Included: Go Direct ORP (includes Go Direct Electrode Amplifier) Micro USB Cable

283.30 CHF*
PH-METRE
Le pH-mètre est constitué d’une électrode Ag-AgCl gel et de son amplificateur. Il peut être utilisé pour toutes les expériences de pH-métrie en chimie ou biologie. Il possède de la mémoire pour stocker des étalonnages qui seront automatiquement utilisés par le logiciel. Cela permet d'utiliser un étalonnage propre à chaque capteur sans avoir besoin de réétalonner à chaque utilisation. Un amplificateur d'électrode peut être acheté séparément pour connecter une autre électrode. Electrode AG-AgCl gel Mesure des pH de 0 à 14 Temps de réponse : 90% de la valeur finale en 1 seconde Protection en epoxy sur le corps de l’électrode Fonctionne de 5 à 80°C Résolution avec CBL/CBL2: 0,02 unités pH Résolution avec LabPro, LabQuest: 0,005 unités pH pH isopotentiel : pH 7 (point auquel la température n'a pas d'effet sur la sortie) Sortie : 59.2 mV/pH à 25°C Mémoire pour stocker les étalonnages   Garantie 5 ans

254.80 CHF*
Go Direct® Glass-Body pH Sensor
Description This high-quality glass body pH sensor can be used in non-aqueous solutions and solutions that contain organic solvents, strong acids, or strong bases. The electrode features a sealed, gel-filled Ag-AgCl combination reference electrode and uses a BNC connector.  Specifications pH range: 0–14 Type: Glass shaft, sealed combination electrode with Ag/AgCl reference Temperature range: 0–80°C (readings not compensated) Accuracy ±0.2 pH units (factory calibration) ±0.05 pH units (user calibration) Response time: 2 s (to 90% of full reading in aqueous buffer) 5 s (to 90% of full reading in 50% acetonitrile) Shaft diameter: 12 mm OD Shaft material: glass

344.50 CHF*
Ignorer la galerie de produits

Similar Items

DO Calibration Solution
This is a replacement bottle of sodium sulfite, used for the zero dissolved oxygen calibration point. One bottle is included with the DO Probe.

9.80 CHF*
Primary Productivity Kit
Cette trousse est un accessoire pour l'un de nos laboratoires de biologie les plus populaires, Primary Productivity. La trousse se compose d'une boîte de 7 bouteilles en plastique, de 7 bouchons en caoutchouc et d'un ensemble de moustiquaires.

112.10 CHF*
Membrane for DO Sensor
This is a replacement membrane cap for a Dissolved Oxygen Probe. The membranes on DO Probes have a limited lifespan, the duration of which varies with frequency and care of use. One extra membrane cap is included with the DO Sensor.

38.70 CHF*