Passa al contenuto principale Salta alla ricerca Passa alla navigazione principale

Go Direct® ORP BNC Electrode

Info sui prodotti "Go Direct® ORP BNC Electrode"

The Go Direct ORP BNC Electrode can be used to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction.

The Go Direct ORP Sensor can be used in a variety of experiments:

  • Determine the equivalence point of an oxidation-reduction titration.
  • Measure the oxidizing ability of chlorine in swimming pools.
  • Investigate the ORP of drinking water.

Specifications:

ORP Electrode

  • Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference
  • Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
  • ORP element: 99% pure platinum band sealed on a glass stem
  • Temperature range:
    • 0 to 60°C
    • 12 mm OD
    • Impedance: ~20 kΩ at 25ºC

Included:

  • Go Direct ORP BNC(does not includes Go Direct Electrode Amplifier)
Bildungsstufe: Scuola media, Scuole medie superiori e professionali, Secundario II
Fach: chimica, fisica
Fachbereich: Biologie, Chemie
Hersteller: Vernier

0 di 0 valutazioni

Valutazione media di 0 su 5 stelle

Formula una valutazione!

Condividi le tue esperienze con il prodotto con altri clienti.


Salta la galleria dei prodotti

Accessory Items

Advanced Chemistry with Vernier
Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor. ​Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments. Use it in addition to​ ​Vernier Chemistry Investigations for Use with AP Chemistry​ (APCHEM) ​for a comprehensive set of topics.​

Da CHF 83.40*
Vernier Chemistry Investigations for Use with AP* Chemistry - Print and E-Book
This lab book provides Advanced Placement (AP) Chemistry students with 16 inquiry-based laboratory experiments aligned with the inquiry investigations published by The College Board. Each experiment guides students to investigate key principles of AP Chemistry using electronic sensors to collect important data. This lab book also provides a comprehensive set of resources for the AP Chemistry teacher, including sample data, sample analysis and calculations, and helpful guides to preparing reagents and chemical solutions. In addition, a carefully chosen set of step-by-step instructions for operating probes and software is included to help students make the best use of available lab time, while retaining the spirit of an inquiry environment.

CHF 120.20*
Electrode Tip Guard (2 Pack)
Replacement tip guards for Glass-body pH Electrode.

CHF 24.40*
Electrode Support
The Vernier Electrode Support connects to all standard ring-stand posts to keep sensors firmly in place during an experiment. The Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. The clamp end makes connecting to ring stands easy, accommodating post diameters between ~0.5 and 1 cm. The grooves on the Electrode Support to hold the wire leads for electroplating or electrolysis experiments.

CHF 20.30*
Investigating Chemistry through Inquiry
The Investigating Chemistry through Inquiry lab book contains 25 inquiry-based chemistry investigations. The book is authored by two long-time chemistry teachers, Donald L. Volz and Ray Smola, who have enjoyed using the inquiry method in their own instruction. Each experiment includes a preliminary activity, teacher information, sample researchable questions, and sample data for those researchable questions. If you are new to inquiry-based instruction, the extensive Instructor Sections that are included with each investigation will help guide you through the inquiry-based style of chemistry instruction. Included with Investigating Chemistry through Inquiry  Electronic Version 25 inquiry-based, chemistry investigations Access to up-to-date versions of the experiments Essential teacher information for successful inquiry investigations Suggested researchable questions, sample data, and graphs A generous site license—buy one book and duplicate the labs for your class Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

Da CHF 83.40*
Go Direct™ Electrode Amplifier
The Go Direct Electrode Amplifier offers an affordable way to expand your experiment options. Its BNC connector provides the flexibility to attach and remove a Vernier electrode, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. You can explore pH one day and potassium concentrations the next.   Because the Go Direct Electrode Amplifier is compatible with third-party electrodes, students learn consistent calibration and handling techniques on one amplifier using one software program. When electrodes expire or become damaged you need only replace the electrode—lowering your overall equipment costs.   Rechargeable Battery—Ready When You Are The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 2 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.   Wired or Wireless—The Flexibility to Choose Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory. Specifications Units: pH or mV Input range (mV): ±1000 mV Input range (pH): 0 to 14 pH Accuracy with new electrode (mV): ±20 mV Accuracy with new electrode (pH): ±0.2 Connections: Wireless: Bluetooth Wired: USB

CHF 181.40*
Salta la galleria dei prodotti

Similar Items

Go Direct™ ORP Sensor
The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It directly connects wirelessly via Bluetooth® or wired via USB to your platform. Use the Go Direct ORP Sensor to measure the ability of a solution to act as an oxidizing agent and to quantify ion activity. This sensor measures the capacity of a solution to either release or accept electrons from chemical reactions. This sensor is comprised of an ORP electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. The Go Direct ORP Sensor can be used in a variety of experiments: Determine the equivalence point of an oxidation-reduction titration. Measure the oxidizing ability of chlorine in swimming pools. Investigate the ORP of drinking water. Specifications: ORP Electrode Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Temperature range: 0 to 60°C 12 mm OD Impedance: ~20 kΩ at 25ºC Electrode Amplifier Units: mV Input range: ±1000 mV Connections: Wireless: Bluetooth Wired: USB Included: Go Direct ORP (includes Go Direct Electrode Amplifier) Micro USB Cable

CHF 283.30*
ORP Sensor
The Oxidation-Reduction Potential (ORP) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. Use the ORP Sensor to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction. Type:Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution:pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Redox potential range:-450 to +1100 mV User manual

CHF 285.40*
Go Direct® Ammonium Ion-Selective Electrode BNC
Dieser Go Direct Sensor mit ionenselektiver Elektrode für Ammonium (NH4) eignet sich zur Messung des Potentials (mV) und zur Berechnung der Konzentration von NH4-Ionen in wässrigen Lösungen. Die Verbindung kann kabellos über Bluetooth® oder kabelgebunden mit USB an Interface, PC, Tablet, Smartphone oder Chromebook erfolgen. Messbereich (mV): ±1000 mV Messbereich (Konzentration): 1 bis 18.000 mg/L (oder ppm) Genauigkeit: ±10% des Messbereichs (kalibriert 1 bis 100 mg/L) Querempfindlichkeiten: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+ pH-Bereich: 2-7 (keine pH-Kompensation) Temperaturbereich: 0-40°C (keine Temperaturkompensation) Elektrodensteigung: 55 ±3 mV/Dekade bei 25°C Elektrodenwiderstand: 0,1 bis 5 MΩ Minimaler Probenumfang: muss 2,8 cm eingetaucht werden. Konnektivität: Bluetooth, USB

CHF 548.40*