Informations sur le produit "Go Direct® Ammonium Ion-Selective Electrode BNC"
Dieser Go Direct Sensor mit ionenselektiver Elektrode für Ammonium (NH4) eignet sich zur Messung des Potentials (mV) und zur Berechnung der Konzentration von NH4-Ionen in wässrigen Lösungen. Die Verbindung kann kabellos über Bluetooth® oder kabelgebunden mit USB an Interface, PC, Tablet, Smartphone oder Chromebook erfolgen.
Messbereich (mV): ±1000 mV
Messbereich (Konzentration): 1 bis 18.000 mg/L (oder ppm)
Genauigkeit: ±10% des Messbereichs (kalibriert 1 bis 100 mg/L)
Water Quality with Vernier has 18 water quality tests, including pH, total dissolved solids, dissolved oxygen, BOD, flow rate, turbidity, nitrates, and phosphates. All nine tests in the Water Quality Index (WQI) are supported. A comprehensive introduction is included for each test, providing important background information for the students.
The printed version includes access to the electronic edition online.
The Go Direct™ Charge Station is the perfect solution for charging your Go Direct Sensors. Each charge station has sixteen charging ports—eight USB and eight wand-style sensor ports. LED lights on the Go Direct sensors will show charging status. The Go Direct Charge Station is also compatible with Go Wireless devices. USB cables not included.
Mit Graphical Analysis Pro können Schüler wissenschaftliche Daten, die von Vernier-Sensoren erfasst wurden, visualisieren und so ihr Verständnis und ihr Engagement mit Hilfe von aussagekräftigen Echtzeitgrafiken verbessern. Diese einfach zu bedienende Anwendung funktioniert auf den im Klassenzimmer üblichen Betriebssystemen.
Graphical Analysis Pro enthält ausserdem wichtige Funktionen, die dreidimensionales Lernen, kritisches Denken, die Zusammenarbeit von Schülern, asynchronen Unterricht und eine tiefere Analyse von Versuchsphänomenen fördern.
Schauen Sie sich die Vergleichstabelle unten an, um zu sehen, was Graphical Analysis Pro Ihrem Klassenzimmer hinzufügen kann.
Fördern Sie das Verständnis Ihrer Schüler für komplexe wissenschaftliche Konzepte durch die gemeinsame Nutzung von Daten in Echtzeit. Wenn die Schüler die gesammelten Experimentdaten direkt vor ihren Augen sehen, können sie abstrakte Ideen mit der realen Welt verbinden.
Beispiel-Experimente
Greifen Sie auf Dutzende von Experimentiervideos zu, die mit echten Daten synchronisiert sind, um sowohl das Lernen aus der Ferne als auch vor Ort zu unterstützen. Diese Beispielexperimente helfen Ihren Schülern, ein Experiment zu erleben, selbst wenn keine Laborausrüstung zur Verfügung steht. Sie können die Beispielexperimente auch für Vorversuche und zur Differenzierung des Unterrichts verwenden.
Datenerfassung
Erfassen Sie Experimentdaten von mehreren Sensoren gleichzeitig mit einer Mehrkanalschnittstelle, wie z. B. LabQuest Stream® oder mehreren Go Direct®-Sensoren.
Visualisierung von Daten
Helfen Sie Ihren Schülern bei der Visualisierung von Experimentdaten - und erhöhen Sie das Verständnis und die Merkfähigkeit - mit detailreichen, anpassbaren Grafiken.
Grafische Analyse Pro Fernunterricht
Gemeinsame Nutzung von Daten
Fördern Sie das Verständnis Ihrer Schüler für komplexe wissenschaftliche Konzepte durch die gemeinsame Nutzung von Daten in Echtzeit. Wenn die Schüler die gesammelten Experimentdaten direkt vor ihren Augen sehen, können sie abstrakte Ideen mit der realen Welt verbinden.
Mit Daten synchronisierte Videos
Passen Sie den Unterricht und das Lernen mithilfe Ihrer mit Daten synchronisierten Experimentiervideos an. Ihre Schüler können sogar ihre eigenen Videos hochladen und mit anderen teilen.
Beispiel-Experimente
Greifen Sie auf Dutzende von Experimentiervideos zu, die mit echten Daten synchronisiert sind, um sowohl das Lernen aus der Ferne als auch vor Ort zu unterstützen. Diese Beispielexperimente helfen Ihren Schülern, ein Experiment zu erleben, selbst wenn keine Laborausrüstung zur Verfügung steht. Sie können die Beispielexperimente auch für Vorversuche und zur Differenzierung des Unterrichts verwenden.
Erweiterte Datenanalyse
Bieten Sie Ihren Schülern mehr Optionen für eine tiefere Analyse mit benutzerdefinierten Kurvenanpassungen und berechneten Spalten. Diese Funktionen ermöglichen die Anpassung von Gleichungen und Ausdrücken direkt in der App zur sofortigen Analyse.
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of an Ammonium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use.
La pince Go Direct Sensor s'attache solidement à un capteur Go Direct de type baguette, et la longe incluse sert de sangle pour prévenir les chutes accidentelles lors d'enquêtes sur le terrain.
Détendez-vous en sachant que les élèves ne laisseront pas tomber leurs capteurs pendant qu'ils prélèvent des échantillons d'eau sur place à l'aide de la sonde d'oxygène dissous optique Go Direct ou suspendent une sonde de température Go Direct dans un arbre pour mesurer la température atmosphérique.
La pince Go Direct ne peut pas être utilisée avec le câble USB branché. Cet accessoire ne rendra pas un capteur étanche à l'eau, pas plus qu'il ne doit être utilisé pour faire tourner un capteur sur un chemin circulaire.
The Go Direct Electrode Amplifier offers an affordable way to expand your experiment options. Its BNC connector provides the flexibility to attach and remove a Vernier electrode, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode. You can explore pH one day and potassium concentrations the next.
Because the Go Direct Electrode Amplifier is compatible with third-party electrodes, students learn consistent calibration and handling techniques on one amplifier using one software program. When electrodes expire or become damaged you need only replace the electrode—lowering your overall equipment costs.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Graphical Analysis™ 4 app or LabQuest 2 App. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.
Specifications
Units: pH or mV
Input range (mV): ±1000 mV
Input range (pH): 0 to 14 pH
Accuracy with new electrode (mV): ±20 mV
Accuracy with new electrode (pH): ±0.2
Connections:
Wireless: Bluetooth
Wired: USB
The Vernier Electrode Support connects to all standard ring-stand posts to keep sensors firmly in place during an experiment.
The Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place.
The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors.
The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp.
The clamp end makes connecting to ring stands easy, accommodating post diameters between ~0.5 and 1 cm. The grooves on the Electrode Support to hold the wire leads for electroplating or electrolysis experiments.
Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+.
The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.
Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
Specifications: User manual
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample.
The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.
Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
NO3-BTA User manual
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample.
The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.
Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
NO3-BTA User manual
Dieser Go Direct Sensor mit ionenselektiver Elektrode für Ammonium (NH4) eignet sich zur Messung des Potentials (mV) und zur Berechnung der Konzentration von NH4-Ionen in wässrigen Lösungen. Die Verbindung kann kabellos über Bluetooth® oder kabelgebunden mit USB an Interface, PC, Tablet, Smartphone oder Chromebook erfolgen.
Messbereich (mV): ±1000 mV
Messbereich (Konzentration): 1 bis 18.000 mg/L (oder ppm)
Genauigkeit: ±10% des Messbereichs (kalibriert 1 bis 100 mg/L)
Querempfindlichkeiten: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+
pH-Bereich: 2-7 (keine pH-Kompensation)
Temperaturbereich: 0-40°C (keine Temperaturkompensation)
Elektrodensteigung: 55 ±3 mV/Dekade bei 25°C
Elektrodenwiderstand: 0,1 bis 5 MΩ
Minimaler Probenumfang: muss 2,8 cm eingetaucht werden.
Konnektivität: Bluetooth, USB
Utilisez l'électrode sélective d'ions potassium Go Direct pour mesurer sans fil les niveaux d'ions potassium.
Le connecteur BNC polyvalent permet aux étudiants de remplacer facilement l'électrode lorsqu'elle expire ou est endommagée. Vous n'avez qu'à remplacer l'électrode et non le capteur entier, ce qui réduit vos coûts d'équipement.
L'électrode sélective pour ions potassium Go Direct est dotée d'une électrode de type combiné, non rechargeable et remplie de gel. Comme toutes les autres membranes ISE en PVC, la membrane de l'ISE a une durée de vie limitée. Cependant, le module remplaçable de l'ISE vous permet de vous débarrasser du module de membrane usagé et de le remplacer par un nouveau module.
Data from the Calcium ISE can give a good indication of hardness of water (as Ca2+). The concentration of Calcium is also used as an endpoint indicator in EDTA-Ca/Mg hardwater titrations.
The Calcium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one.
Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
CA-BTA User manual
The Go Direct ORP BNC Electrode can be used to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction.
The Go Direct ORP Sensor can be used in a variety of experiments:
Determine the equivalence point of an oxidation-reduction titration.
Measure the oxidizing ability of chlorine in swimming pools.
Investigate the ORP of drinking water.
Specifications:
ORP Electrode
Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
ORP element: 99% pure platinum band sealed on a glass stem
Temperature range:
0 to 60°C
12 mm OD
Impedance: ~20 kΩ at 25ºC
Included:
Go Direct ORP BNC(does not includes Go Direct Electrode Amplifier)
The Go Direct pH BNC Electrode is a gel-filled combination pH electrode designed to make measurements in the pH range of 0 to 14. A polycarbonate body that extends below the glass sensing bulb of the electrode makes this probe ideal for the demands of a middle school, high school, or university level science class or for making measurements in the environment. The gel-filled reference half cell is sealed—it never needs to be refilled.
Specifications
Type: Sealed, gel-filled polycarbonate body, Ag/AgCl
Response Time: 90% of final reading in 1 second
Temperature Range: 5 to 80°C (readings not compensated)
12 mm outer diameter
Range: pH 0–14
Isopotential pH: pH 7 (point at which temperature has no effect on output)
BNC Connector
Les données obtenues à l'aide de l'électrode sélective pour ions calcium Go Direct sans fil peuvent donner une bonne indication de la dureté de l'eau (sous forme de Ca2+). La concentration de calcium est aussi utilisée comme paramètre dans les titrages EDTA-Ca/Mg d'eau dure.
Le connecteur BNC polyvalent permet aux étudiants de remplacer facilement l'électrode lorsqu'elle expire ou est endommagée. Vous n'avez qu'à remplacer l'électrode et non le capteur entier, ce qui réduit vos coûts d'équipement.
L'électrode sélective d'ions de calcium Go Direct est dotée d'une électrode de type combiné, non rechargeable et remplie de gel. Comme toutes les autres membranes ISE en PVC, la membrane de l'ISE a une durée de vie limitée. Cependant, le module remplaçable de l'ISE vous permet de vous débarrasser du module de membrane usagé et de le remplacer par un nouveau module.
Batterie rechargeable — Prêt lorsque vous êtes
La batterie rechargeable robuste offre une longue autonomie et assure un fonctionnement toujours prêt lors de l'utilisation du capteur sans fil. Surveillez la durée de vie de la batterie directement à partir de notre application Vernier Graphical Analysis® primée, ainsi que de LabQuest® 3. Si la batterie est épuisée, il suffit de connecter le capteur au câble de charge et de continuer à collecter, sans interruption ni inconvénient pour vous ou vos élèves.
Sans fil ou filaire — La flexibilité du choix
Nos capteurs Go Direct se connectent directement à votre appareil mobile, Chromebook™ ou à votre ordinateur à l'aide de notre application Vernier Graphical Analysis®. Les capteurs Go Direct peuvent être utilisés par câble via USB ou sans fil via la technologie sans fil Bluetooth®, ce qui vous permet de choisir la solution qui convient le mieux à votre classe ou à votre laboratoire.
Remarque: Nous vous recommandons de ne pas acheter les modules de remplacement ISE trop longtemps avant leur date d'utilisation prévue, car ils se détériorent pendant qu'ils sont entreposés sur les étagères.Important: Les électrodes sélectives d'ions requièrent une bonne technique chimique et un étalonnage minutieux pour obtenir des résultats précis; elles ne sont pas recommandées pour les élèves du collège ou du primaire.