Passa al contenuto principale Salta alla ricerca Passa alla navigazione principale

Water Quality with Vernier - Print and E-Book

Info sui prodotti "Water Quality with Vernier - Print and E-Book"

Water Quality with Vernier has 18 water quality tests, including pH, total dissolved solids, dissolved oxygen, BOD, flow rate, turbidity, nitrates, and phosphates. All nine tests in the Water Quality Index (WQI) are supported. A comprehensive introduction is included for each test, providing important background information for the students.

The printed version includes access to the electronic edition online.

 

Bildungsstufe: Scuola media, Scuole medie superiori e professionali
Fach: Vernier, biologia, chimica
lingua: inglese

0 di 0 valutazioni

Valutazione media di 0 su 5 stelle

Formula una valutazione!

Condividi le tue esperienze con il prodotto con altri clienti.


Salta la galleria dei prodotti

Accessory Items

Nitrate Ion-Selective Electrode
Nitrate concentration, which can be increased by acidic rainfall, fertilizer runoff from fields, and plant or animal decay or waste, is an important parameter in nearly all water quality studies. Use the Nitrate ISE to determine the concentration of the nitrate ion in a water sample. The Nitrate ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   NO3-BTA User manual

CHF 713.50*
Sensore di salinità Go Direct®
Il sensore di salinità Go Direct misura in modo semplice e preciso il contenuto totale di sale disciolto in una soluzione acquosa. È possibile misurare la salinità compensata dalla temperatura o non compensata dalla temperatura, insieme alla temperatura. Misura l'acqua con un'ampia varietà di salinità, dall'acqua salmastra all'acqua oceanica, fino ad ambienti iper-salini. Puoi anche studiare come la salinità influenzi il galleggiamento o monitorare i valori di salinità negli estuari dove l'acqua dolce si mescola all'acqua oceanica. È dotato di un sensore di temperatura incorporato per leggere contemporaneamente salinità e temperatura. La compensazione automatica della temperatura consente agli studenti di calibrare la sonda in laboratorio e quindi effettuare misure all'aperto senza che i cambiamenti di temperatura influiscano sui dati. Questa compensazione della temperatura può essere disattivata per effettuare studi sulla salinità in funzione della temperatura. Specifiche Gamma di sensore di salinità: da 0 a 50 ppt (da 0 a 50.000 ppm)

CHF 426.00*
Suggerimento
Nuovo
Go Direct® Air Quality Sensor
Spedizione prevista per giugno 2026Il sensore di qualità dell'aria Go Direct aiuta gli studenti ad approfondire questioni concrete relative alla qualità dell'aria che respiriamo, fornendo dati misurabili proprio nei luoghi in cui vivono e studiano.Progettato per l'uso nelle scuole superiori e nelle università, questo sensore resistente consente il monitoraggio sia in ambienti interni che esterni, permettendo agli studenti di seguire l'andamento degli inquinanti nel tempo, analizzare i modelli spaziali e mettere in relazione la qualità dell'aria con la salute umana ed ecologica.Rendere la qualità dell'aria tangibile, locale e misurabile per gli studenti. Il sensore di qualità dell'aria Go Direct trasforma la qualità dell'aria da concetto astratto a dato misurabile, in un formato pronto per l'uso in classe. Fornisce a insegnanti e studenti gli strumenti necessari per studiare scientificamente l'inquinamento, pensare in modo sistemico e comprendere come le condizioni ambientali influenzino direttamente la salute umana ed ecologica, proprio nel luogo in cui vivono e studiano.Idee per approfondimentiConfrontare la qualità dell'aria interna ed esterna.Monitorare il particolato in prossimità di strade, parcheggi o spazi verdi.Analizzare i cambiamenti della qualità dell'aria durante le ore di punta del traffico o i cambiamenti meteorologici quotidiani.Osservare l'andamento dell'ozono nelle giornate soleggiate rispetto a quelle nuvolose.Indagare su come i diversi tipi di piani cottura influenzano i livelli di CO2 e PM.Misura i principali inquinanti atmosfericiParticolato (PM1, PM2,5 e PM10)Ozono troposferico (O3)Biossido di azoto (NO2)Biossido di zolfo (SO2)Anidride carbonica (CO2)Indice dei composti organici volatili (Indice VOC)Misura le condizioni ambientaliTemperatura Umidità relativa Pressione barometrica e della stazioneCaratteristiche principaliRaccolta dati in tempo reale sulla qualità dell'aria tramite tecnologia wireless Bluetooth®Registrazione dati remota per indagini a lungo termine o in luoghi remoti, senza necessità di connessioneIl sistema di navigazione satellitare globale (GNSS) integrato consente la geolocalizzazioneResistente per uso interno ed esternoRegistrazione dati remota: supera i limiti del wirelessQuesto sensore Go Direct è in grado di registrare i dati in remoto! Questa funzione consente ai sensori di memorizzare i dati direttamente nella loro memoria interna: l'ideale per indagini che si estendono oltre i tipici intervalli di connessione, come il monitoraggio ambientale a lungo termine o i lanci di razzi. Funziona perfettamente con la nostra pluripremiata app Vernier Graphical Analysis®, consentendo agli studenti di visualizzare i propri dati e stabilire collegamenti chiave tra concetti scientifici astratti e fenomeni del mondo reale. Scopri di più sulla registrazione dati in remoto.Batteria ricaricabile: pronta quando lo sei tuLa robusta batteria ricaricabile offre una lunga durata e garantisce un funzionamento sempre pronto quando si utilizza il sensore in modalità wireless. Monitora la durata della batteria direttamente dalla nostra pluripremiata app Vernier Graphical Analysis®, così come da LabQuest® 3. Se la batteria si sta scaricando, basta collegare il sensore al cavo di ricarica e continuare a raccogliere dati, senza interruzioni o inconvenienti per te o i tuoi studenti.Wireless o cablato: la flessibilità di scegliereI nostri sensori Go Direct si collegano direttamente al tuo dispositivo mobile, Chromebook™ o computer utilizzando la nostra app Vernier Graphical Analysis®: non è necessario acquistare attrezzature o software aggiuntivi. I sensori Go Direct possono essere utilizzati via cavo tramite USB o in modalità wireless tramite la tecnologia Bluetooth®, consentendoti di scegliere la soluzione migliore per la tua classe o il tuo laboratorio.Go Direct Air Quality has the following channels PM1.0PM2.5PM10CO2NO2SO2O3VOC IndexTemperatureRelative HumidityBarometric PressureStation PressureLatitudeLongitudeAltitudeSpecificationsPM Mass Concentration Specified Range: 0–1000 µg/m3PM1 size range: 0.3–1µgPM2.5 size range: 0.3–2.5µgPM10 size range: 0.3–10µgCO2 Range: 0–5,000 ppmNO2 Range: 0-2000ppb SO2 Range: 0-2000ppbO3 Range: 0-2000ppbVOC Index: 1–500Temperature Range: 10–40℃ (-10℃ min, 50℃ max short term)Relative Humidity Range: 20–80% (10% min, 90% max short term)Station Pressure Range: 260–1260hPaMaximum sampling rate: 1 sample/s

CHF 813.40*
Flow Rate Sensor
Il sensore di portata misura la velocità dell'acqua nello studio della portata, del flusso e del trasporto di sedimenti di un torrente o di un fiume. Il sensore di portata può essere utilizzato per studi ambientali o di scienze della Terra. I dati di portata possono essere utilizzati per calcolare il valore di portata di un flusso o determinare il trasporto di sedimenti di un flusso. Il sensore di portata comprende 3 barre di sollevamento, che consentono di posizionare la girante a profondità fisse, ed è dotato di un cavo di 5 m che consente all'apparecchiatura di raccolta dati di rimanere a terra. Il sensore di portata è inoltre separato in quattro sezioni per facilitare il trasporto e lo stoccaggio. Gamma: da 0 a 4,0 m/s (da 0 a 13 ft/s) Precisione: ±1% della lettura su scala reale Risoluzione tipica: 0.0012 m/s Intervallo di temperatura (può essere inserito): da 0 a 70°C User manual

CHF 324.10*
Conductivity Probe
The Conductivity Probe determines the ionic content of an aqueous solution by measuring its conductivity. The Conductivity Probe has three ranges, providing optimal precision in any given range. Biology teachers can use this probe to demonstrate diffusion of ions through membranes. Chemistry students are able to quickly investigate the difference between ionic and molecular compounds, strong and weak acids, or ionic compounds that yield different ratios of ions. Environmental science students use it to measure TDS, total dissolved solids. Range: Low Range: 0 to 200 μS/cm (0 to 100 mg/L TDS) Mid Range: 0 to 2000 μS/cm (0 to 1000 mg/L TDS) High Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS) Typical Resolution: Low Range: 0.1 μS/cm (0.05 mg/L TDS) Mid Range: 1 μS/cm (0.5 mg/L TDS) High Range 10 μS/cm (5 mg/L TDS) Accuracy using factory calibration: ±8% of full-scale reading for low range ±3% of full-scale reading for mid range ±4% of full-scale reading for high range Accuracy using custom calibration: ±2% of full-scale reading for each range Response Time: 98% of full-scale reading in 5 seconds, 100% of full-scale in 15 seconds Temperature Compensation: automatic from 5 to 35 °C Temperature Range (can be placed in): 0 to 80 °C Cell Constant: 1.0 cm-1 Description: ABS body, parallel carbon (graphite) electrodes Dimensions: 12 mm OD and 150 mm length   CON-BTA User manual

CHF 297.60*
pH Sensor
Utilizzate il sensore di pH proprio come fareste con un pHmetro tradizionale, con i vantaggi aggiuntivi della raccolta automatica dei dati, della creazione di grafici e dell'analisi dei dati. Le attività tipiche che utilizzano il nostro sensore di pH includono: Titolazioni acido-base Studi sugli acidi e le basi per uso domestico Monitoraggio delle variazioni di pH durante reazioni chimiche o in acquario come risultato della fotosintesi Indagini sulle piogge acide e sui tamponi Analisi della qualità delle acque di torrenti e laghi Se state studiando tamponi Tris o semisolidi di questo tipo, prendete in considerazione il sensore di pH piatto Vernier Tris-Compatible.

CHF 254.80*
Extra-Long Temperature Probe
This probe is designed for outdoor temperature sensing or for measuring temperature at various depths in lakes and streams. It has a 30 m (100 ft) cable. Range:–50˚C to 150˚C Typical Accuracy:±0.2°C Typical Resolution:0.07°C User manual

CHF 234.40*
Turbidity Sensor
Use the Turbidity Sensor to measure the turbidity of freshwater or seawater samples and determine water quality. Simple setup and calibration make it easy to use at the collection site or when you return to the classroom. The Turbidity Sensor measures the turbidity of fresh-water or seawater samples in NTU (Nephelometric Turbidity Units, the standard unit used by most water collection agencies and organizations). Its small, sleek design and simple setup make it easy to use at the collection site or in the classroom. In addition to water quality studies, it can also be used to monitor precipitate formation or algae and yeast populations in chemistry and biology classes. The Turbidity Sensor includes high-quality Hach StablCal™ 100 NTU standard for quick calibration and a high-grade glass cuvette for your water sample. Range:0 to 200 NTU Typical Resolution:0.25 NTU Accuracy:±2 NTU for readings under 25 NTU±5% of readings above 25 NTU User manual

CHF 305.80*
Campionatore di profondità dell'acqua
Nessun groviglio di cavi con questo campionatore efficiente ed economico. Un unico cavo consente di prelevare un campione d'acqua da 1,5 litri da qualsiasi profondità in laghi, fiumi o stagni. Il design a flusso continuo consente un campionamento valido per misurare la temperatura e la qualità dell'acqua. È fornito un cavo da 14 metri.

CHF 262.90*
Calcium Ion-Selective Electrode
Data from the Calcium ISE can give a good indication of hardness of water (as Ca2+). The concentration of Calcium is also used as an endpoint indicator in EDTA-Ca/Mg hardwater titrations. The Calcium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   CA-BTA User manual

CHF 713.50*
Go Direct™ SpectroVis® Plus Spectrophotometer
Lo spettrofotometro Go Direct SpectroVis Plus misura rapidamente l'intera lunghezza d'onda. Si collega direttamente alla piattaforma in modalità wireless tramite Bluetooth® o cablato via USB. Introducete i vostri studenti alla spettroscopia con l'economico spettrofotometro Go Direct SpectroVis Plus. In grado di collegarsi wireless o via USB, questo dispositivo può facilmente raccogliere l'intera lunghezza d'onda (assorbanza, trasmissione percentuale o intensità) in meno di un secondo. Una volta determinata la lunghezza d'onda di picco, è possibile stabilire la concentrazione di una soluzione (legge di Beer) o monitorare la velocità di reazione. Un percorso luminoso ridotto consente allo spettrofotometro Go Direct SpectroVis Plus di essere utilizzato per microlaboratori e applicazioni biochimiche con micro e semi-micro cuvette. Lo spettrofotometro Go Direct SpectroVis Plus può essere utilizzato in diversi esperimenti di spettroscopia: Determinare la lunghezza d'onda del picco per raccogliere dati sulla concentrazione della soluzione per studi sulla legge di Beer o per monitorare le velocità di reazione. Raccogliere uno spettro a lunghezza d'onda completa per misurare l'assorbanza, la trasmittanza percentuale, la fluorescenza (a 405 nm o 500 nm di eccitazione) o le emissioni. Condurre esperimenti di cinetica enzimatica. Effettuare studi sull'equilibrio di assorbanza vs tempo o assorbanza vs concentrazione. Effettuare biotest colorimetrici o fluorescenti. Utilizzate lo spettrofotometro a fibra ottica (VSP-FIBER) per misurare le emissioni provenienti da prove alla fiamma o da altre sorgenti luminose. Per un'analisi più dettagliata delle emissioni, prendete in considerazione lo spettrometro Vernier Emissions (VSP-EM). Spettroscopia con Go Direct SpectroVis Plus Per utilizzare lo spettrofotometro Go Direct SpectroVis Plus, scarica l'app gratuita Spectral Analysis. L'app è compatibile con computer, Chromebook e dispositivi mobili. Gli studenti possono anche collegarsi a LabQuest 2 o a un computer con Logger Pro per effettuare analisi. Specifiche Intervallo di lunghezze d'onda: 380 nm–950 nm Supporto per fluorescenza: due sorgenti di eccitazione centrate a 405 nm e 500 nm Intervallo di lunghezza d'onda riportato: ~1 nm tra i valori riportati (raccoglie 570 valori) Dimensioni: 16 cm x 10 cm x 5 cm Sorgenti luminose: Lampadina bianca a incandescenza, durata di circa 8.000 ore, calibrazione in un solo passaggio. Basato su LED, durata di circa 100.000 ore. Nessuna alimentazione esterna è richiesta.

CHF 1’037.70*
Vernier Lanyard
The lanyard works as a LabQuest neck strap to prevent accidental drops while doing field studies. It can also be attached to a calculator cradle and used with a LabPro or CBL 2.

CHF 10.10*
Go Direct® Elettrodo ione-selettivo di potassio
Utilizzare l'elettrodo Go Direct Potassium Ion-Selective per misurare i livelli di ioni di potassio in modalità wireless. Il versatile connettore BNC consente agli studenti di sostituire facilmente l'elettrodo quando scade o si danneggia. Basta sostituire l'elettrodo e non l'intero sensore, riducendo così i costi complessivi dell'attrezzatura. Il Go Direct Potassium Ion-Selective Electrode ha uno stile combinato, non ricaricabile, pieno di gel. Come tutte le altre membrane in PVC ISE, la membrana su ISE ha un'aspettativa di vita limitata. Tuttavia, il modulo sostituibile di ISE consente di scartare semplicemente il modulo di membrana usato e sostituirlo con uno nuovo.

CHF 703.30*
Ammonium Ion-Selective Electrode
Use the Ammonium ISE to measure levels of ammonium ions introduced from fertilizers. It can also indicate aqueous ammonia levels if sample solutions are acidified to convert NH3 to NH4+. The Ammonium ISE has a combination-style, non-refillable, gel-filled electrode. Like all other PVC ISE membranes, the membrane on the ISE has a limited life expectancy. However, the replaceable module of ISE allows you to simply discard the used membrane module, and replace it with a new one. Note: We recommend that you do not purchase ISE replacement modules too far in advance of their expected time of use as degradation occurs while they are stored on the shelf. Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.     Specifications: User manual

CHF 672.70*
PAR Sensor
The PAR (Photosynthetically Active Radiation) Sensor reports the Photosynthetic Photon Flux Density (PPFD), which corresponds to micromoles of photons per meter squared per second (μmol m-2 s-1). This is the power of electromagnetic radiation in the spectral range that is used by plants for photosynthesis (400–700 nm). It features a waterproof sensor head and can be used to measure PPFD from sunlight and electric light sources. This sensor is ideal for experiments investigating photosynthesis and primary productivity and can be used in many agricultural and environmental science applications. PAR Range:0 to 2000 μmol m-2 s-1 (PPFD) in full sun Absolute Accuracy:±5% Typical Resolution:1 μmol m-2 s-1 (PPFD) User manual

CHF 754.30*
Sensore di salinità
Permette di misurare facilmente e con grande accuratezza il contenuto totale dei sali disciolti in acqua. La salinità totale è un parametro molto importante nell’analisi delle acque di mare o degli estuari, dove l’acqua dolce dei fiumi si riversa nel mare. Il livello di salinità del mare è pressoché costante (circa 35 ppt o 35.000 mg/L), mentre negli estuari salmastri può essere compreso tra 1 e 10 ppt. La portata del sensore di salinità arriva fino a 50 ppt e ciò significa che è possibile effettuare misure in un ampia gamma di salinità diverse, dall’acqua dolce a quella di mare, fino ad arrivare anche allo studio di ambienti ipersalini. User manual

CHF 428.10*
Stainless Steel Temperature Probe
The Stainless Steel Temperature Probe is a rugged, general-purpose temperature sensor that can be used in organic liquids, salt solutions, acids, and bases. Use it as you would use a thermometer for experiments in chemistry, physics, biology, Earth science, and environmental science. Temperature range:–40 to 135°C (–40 to 275°F) Typical Resolution:0.17°C (–40 to 0°C)0.03°C (0 to 40°C)0.1°C (40 to 100°C)0.25°C (100 to 135°C) Accuracy:±0.2°C at 0°C±0.5°C at 100°C User manual

CHF 87.60*
Chloride Ion-Selective Electrode
The concentration of the Chloride ion gives a quick measurement of salinity of water samples. Use the Chloride ISE to measure chloride levels in ocean saltwater or salt in food samples. The Chloride ISE has a combination-style, non-refillable, gel-filled electrode. Unlike other ISEs available from Vernier, the Chloride ISE has a solid-state membrane that does not need to be replaced.   Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.   CL-BTA User manual

CHF 672.70*
Salta la galleria dei prodotti

Similar Items

Investigating Environmental Science through Inquiry
Investigating Environmental Science through Inquiry contains 34 inquiry-based, environmental science investigations. Each experiment includes a preliminary activity, teacher information, sample researchable questions, and sample data. The lab book uses data collection-technology to look at local issues and solutions. Labs are correlated to Advanced Placement (AP) and International Baccalaureate (IB) standards. Topics covered include: Earth Systems and Resources/Air and Water Earth Systems and Resources/Soil The Living World Global Change and Population Energy Resources and Consumption Pollution The inquiry style used is based on recommendations from the National Research Council report, Learning and Understanding: Improving Advanced Study of Mathematics and Science in U.S. High Schools (2002) and leading inquiry-based learning experts.

Da CHF 83.40*