Skip to main content Skip to search Skip to main navigation

ISE Ammonium Low Standard

Product information "ISE Ammonium Low Standard"

The High and Low ISE standards are used to calibrate our Ammonium Ion-Selective Electrodes.

User Manual - NH4-LST

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

ISE Ammonium High Standard
The High and Low ISE standards are used to calibrate our Ammonium Ion-Selective Electrodes. User Manual - NH4-HST

CHF 59.10*
Go Direct® Ammonium Ion-Selective Electrode
The Go Direct Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 18,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+ pH range: 2–7 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Ammonium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (100 mg/L or 100 ppm NH4+ as N) 30 mL bottle of Low Standard solution with SDS (1 mg/L or 1 ppm NH4+ as N) Short-Term ISE Soaking Bottle User Manual - GDX-NH4

CHF 670.70*
Ammonium Ion-Selective Electrode
The Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of Ammonium (NH4+) in aqueous samples. Specifications Range (concentration): 1 to 18,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: K+, Li+, Na+, Cs+, Mg3+, Ca2+, Sr2+, Ba2+ pH range: 4–7.5 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Ammonium Ion-Selective Electrode 30 mL bottle of Ammonium Low Standard (1 mg/L or 1 ppm NH4+ as N) 30 mL bottle of Ammonium High Standard (100 mg/L or 100 ppm NH4+ as N) Short-term ISE soaking bottle User Manual - NH4-BTA

CHF 672.70*
ISE Ammonium Replacement Module
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of an Ammonium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use. User Manual - NH4-MOD

CHF 193.20*
Skip product gallery

Similar Items

ISE Ammonium High Standard
The High and Low ISE standards are used to calibrate our Ammonium Ion-Selective Electrodes. User Manual - NH4-HST

CHF 59.10*
Standard Potassium Solution - Low
The Low and High ISE standards are used to calibrate our Potassium Ion-Selective Electrodes. User Manual - K-LST

CHF 59.10*
ISE Ammonium Replacement Module
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of an Ammonium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use. User Manual - NH4-MOD

CHF 193.20*