The Go Direct SpectroVis Plus Spectrophotometer quickly measures a full wavelength spectrum. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Wavelength Range: 380 nm–950 nm
Support for fluorescence: Two excitation sources centered at 405 nm and 500 nm
Reported Wavelength Interval: ~1 nm between reported values (collects 570 values)
Optical resolution (FWHM): 5.0 nm
Wavelength accuracy: ± 4.0 nm
Photometric accuracy: ± 0.10 A.U.
Dimensions: 15 cm x 9 cm x 4 cm
Light Sources: Incandescent white bulb, approximately 8000 hour lifetime, one-step calibration. LED-based, approximately 100,000 hour lifetime. No external power is required.
Typical scan time: ~2 s
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct SpectroVis Plus Spectrophotometer
15 plastic cuvettes and lids
Mini USB Cable
Power supply
User Manual - GDX-SVISPL-INTL
This is an optical fiber accessory designed exclusively for emission spectrum experiments with Vernier-branded spectrophotometers, including Go Direct® SpectroVis® Plus, Go Direct UV-VIS Spectrophotometer, Go Direct Fluorescence/UV-VIS Spectrophotometer, Vernier UV-VIS, and Vernier Fluorescence/UV-VIS.
User Manual - VSP-FIBER
This completely wireless system simplifies experiment setup and allows basic experiments to be conducted with or without the track.
Description
The Dynamics Cart and Track System with Go Direct Sensor Cart includes essential laboratory equipment for teaching dynamics and kinematics. Using our Go Direct Sensor Cart, students can explore force, position, velocity, and acceleration directly on their Bluetooth®-enabled device—no wires or additional equipment required. Each cart features built-in sensors to simplify experiment setup and allow experiments to be conducted on or off the track.
Specifications
Position resolution: 0.25 mm, reported by default at 1 mm steps
Force range: ±50 N
Accelerometer range: ±160 m/s2
Track length: 1.2 m
Shipping costs standard version:
The standard version 1.2m is sent as PostPac Economy bulky goods. The total shipping costs are CHF 31.00.
Shipping costs long version:
The long track version 2.2m is shipped by freight forwarding. The costs for shipping amount to a total of CHF 74.00.
The BioChamber 2000 is a 2000 mL plastic chamber that can be used with a CO2 Gas Sensor and an O2 Gas Sensor to monitor gaseous carbon dioxide and oxygen levels simultaneously in a closed system.
User Manual - BC-2000
The Combination Dynamics Track and Optical Bench is aluminum and includes a metric scale. Extremely rigid, this 1.2 meter track will not sag under use. The track includes 2 Adjustable Two Foot Levelers.
Dieser Artikel wird mit PostPac Economy Sperrgut versendet. Die Kosten für den Versand sind insgesamt 31 CHF.
This accessory kit can be used with the Go Direct® Rotary Motion Sensor or the Rotary Motion Sensor to study the motion of a physical pendulum; the rotational inertia of disks, rings, and point masses; and the conservation angular momentum.
User Manual - AK-RMV
The Motion Detector Reflector Flag is used to make the setup of motion detector-based experiments less critical. The flag attaches to the cart end with magnets. It increases the size and uniformity of the cart end, serving as a reflector for the Motion Detector. It is compatible with both plastic and metal dynamics carts, but not compatible with Go Direct Sensor Carts or fan carts.
Specifications
Dimensions: About 9.5 cm x 9.5 cm
Mass: About 24 g
User Manual - DTS-FLAG
The Next Generation of Portable Balances for your Classroom
Integrated superior overload protection system rated at 10x capacity protects the balance in demanding classroom environments. Space-saving design allows for stackable storage (excluding 1mg model).
Combined with a simplified 4 button operation, the Scout's large backlit display increases readability in dim lighting conditions, and makes it easier to view results from across a desk or lab bench.
With expanded connectivity options including RS232, USB Host, USB Device, Ethernet and Bluetooth®, the Scout provides added versatility to your data collection and transfer needs.
Through the Scout USB Device Interface (Schnittstelle), compatible models of this series can be used together with Vernier hard- and software. This offers the opportunity to execute time-dependent mass measurements (up to 1 measurement/second).
These spectrum tubes are for the Spectrum Tube Single Power Supply and the Spectrum Tube Carousel Power Supply.
The gas tubes are permanently enclosed in plastic carriers that protect the tubes from breakage. There are no through-the-glass electrodes, so the tubes last far longer than older designs.
The Cart Fan is a modular fan you can add to the Dynamics Cart and Track System and Go Direct® Sensor Carts that gives students the ability to perform kinematics and dynamics experiments.
Specifications
Attaches to Go Direct Sensor Carts and Dynamics Cart and Track System (DTS) Carts
Mounting plate accommodates 1, 2, or 3 fans
Fan(s) can be oriented up to 75°off-center (in 15°intervals)
4 thrust levels (low, medium, high, super)
4 duration levels (1, 3, 6, 60 s)
Includes rechargeable battery and charging cable
What's included
Cart Fan
Mounting Plate with captive screws for Go Direct Sensor Cart
Screws for attaching to DTS Cart
Micro-USB cable for charging
User Manual - DTS-CFAN
The OHAUS CX is a lightweight, portable, compact balance perfectly suited for use in laboratory, industrial, education and home use applications. CX offers a great value without sacrificing accuracy for weighing jobs to 5200g.
The large weighing platform can accommodate larger samples and can also be removed for easy cleaning.
Radio frequency protection allows the CS to deliver stable results even when used in areas in which radio waves may be emitted.
The low profile CS is battery operated or can be powered by a standard AC adapter.
Features:
Display: Liquid crystal display (LCD)
Operation : AC adapter (included) or 3 AA batteries (not included)
Construction: ABS housing, stainless steel pan
Design Features: Mechanical and software overload/underload protection, auto shut-off
Units of measurement:
Gram
Pound:Ounce
Newton
The Go Direct Sensor Cart Accessory Kit includes springs, magnets, masses, and replacement parts for the Go Direct Sensor Cart. The kit makes multiple-collision experiments possible, supporting impulse and momentum/energy conservation experiments, among others.
What's included
Heavy hoop spring bumper (1)
Light hoop spring bumper (1)
Masses (4)
Magnetic bumper (2)
Force sensor hook (3)
Rubber bumper (3)
Anti-roll peg (3)
User Manual - GDX-CART-AK
The Go Direct® UV-VIS Spectrophotometer connects to your device via Bluetooth® wireless technology or USB to generate full spectra, Beer’s law data, and kinetic traces of ultraviolet and visible-absorbing samples (such as aspirin, DNA, proteins, and NADH).
Specifications
Detection modes: Absorbance, %Transmittance, Intensity, and Raw Lamp
Experiment types: Full Spectrum, time-based (kinetics), and event-based (Beer’s law)
Dimensions: 18.5 cm × 17.0 cm × 7.0 cm
Lamp power supply: AC adapter (included)
Bluetooth power supply: USB (USB power adapter included)
Power consumption: 3 A start-up, 500 mA continuous
Light source: Deuterium (UV) and incandescent (VIS)
Detector: Linear CCD
Wavelength range: 220–850 nm
Wavelength reporting interval: ~1 nm
Optical resolution: 3.0 nm (as determined with 486 nm hydrogen emission spectral line FWHM)
Wavelength accuracy: ± 2.0 nm (as determined with holmium oxide NIST standard)
Absorbance photometric accuracy: ± 5.0% (as determined with potassium dichromate NIST standards)
Absorbance photometric range (for best accuracy): 0.1–1.0
Typical scan time: ~2 s
Operating temperature: 15–35°C
Sample format: 10 mm × 10 mm cuvette (two UV quartz cuvettes included)
What's included
Go Direct UV-VIS Spectrophotometer
AC Power Supply
Starna® quartz cuvettes (2)
Mini USB cable
USB Power Adapter
User Manual - GDX-SPEC-UV-EURO
Add a Friction Pad DTS to your Vernier Go Direct Sensor Cart, Standard Cart, Plunger Cart, or Motion Encoder Cart, and watch the carts move under very consistent friction force. Setting the friction amount is as simple as turning a knob.
User Manual - DTS-PAD
Rugged and Reliable Analog Hotplates and Stirrers for General Purpose Heating and Stirring
Powerful stirring and fast heating at an economical price. Safely heat up to 500°C and stir up to 15L with easy to use knob control for simple and reliable everyday heating and stirring in the lab.
Designed to last - the rugged metal housing has a spill resistant design for long life in the lab under harsh conditions. The smooth, chemical-resistant ceramic top plate is perfect for easy clean up.
Safety is of utmost importance - the prominent hot top indicator light illuminates when the heater is above 40°C, keeping the end user safe during all heating applications.
The Rod Clamp is used to attach one end of a Vernier Dynamics Track to a vertical ring stand rod. This configuration is most often used to create a ramp.
User Manual - RC-VDS
The Quartz Cuvettes are a pack of two Spectrosil® Quartz cuvettes for use with UV-VIS spectrophotometers. Each cuvette is a standard rectangular cuvette with two polished (clear) sides.
User Manual - CUV-QUARTZ
The Bumper and Launcher Kit contains accessories for experiments involving the Vernier Dual-Range Force Sensor, the Go Direct Force and Acceleration, and the Dynamics Cart and Track System. These accessories include two hoop springs of different stiffnesses, plus additional bumpers for elastic and inelastic collisions.
User Manual - BLK
The Polarizer/Analyzer Set extends the Optics Expansion Kit to allow students to study polarization of light. Using a Rotary Motion Sensor to record analyzer angle, Malus's Law experiments are easy, detailed, and accurate.
Specifications
Polarizer passes vertically polarized light when oriented at 0° or 180°.
Adjustable Analyzer for Rotary Motion Sensor includes a mount that works with the Vernier Rotary Motion Sensor or the Go Direct® Rotary Motion Sensor to record the analyzer angle.
Adjustable Analyzer includes an angle scale for manual reading of the polarizer angle.
What's included
Adjustable Analyzer (2)
Adjustable Analyzer for Rotary Motion Sensor (1)
Mounting Screws for Rotary Motion Sensor (2)
Belt for Rotary Motion Sensor (1)
User Manual - PAK-OEK
With ultra-safe, patent-pending design, this spectrum tube power supply will provide a simple means of viewing gas discharge spectral lines with any of our spectrometers. Unlike other designs, this system has no exposed high voltage.
What's included
Spectrum Tube Single Power Supply
Spectrum Tube Fiber Optic Holder
User Manual - ST-SPS-INTL
These four 125 gram masses are used to add mass to a cart for dynamics experiments. Compatible only with plastic Vernier carts. Not compatible with older metal dynamics carts.
User Manual - DTS-MASS
CHF 32.60*
This website uses cookies to ensure the best experience possible. More information...