Skip to main content Skip to search Skip to main navigation

Vernier Spectrophotometer Optical Fiber

Product information "Vernier Spectrophotometer Optical Fiber"

This is an optical fiber accessory designed exclusively for emission spectrum experiments with Vernier-branded spectrophotometers, including Go Direct® SpectroVis® Plus, Go Direct UV-VIS Spectrophotometer, Go Direct Fluorescence/UV-VIS Spectrophotometer, Vernier UV-VIS, and Vernier Fluorescence/UV-VIS.

User Manual - VSP-FIBER

Bildungsstufe: Diploma/ Vocational/ Uni
Fach: Vernier, chemistry, physics

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Go Direct™ SpectroVis® Plus Spectrophotometer
The Go Direct SpectroVis Plus Spectrophotometer quickly measures a full wavelength spectrum. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Wavelength Range: 380 nm–950 nm Support for fluorescence: Two excitation sources centered at 405 nm and 500 nm Reported Wavelength Interval: ~1 nm between reported values (collects 570 values) Optical resolution (FWHM): 5.0 nm Wavelength accuracy: ± 4.0 nm Photometric accuracy: ± 0.10 A.U. Dimensions: 15 cm x 9 cm x 4 cm Light Sources: Incandescent white bulb, approximately 8000 hour lifetime, one-step calibration. LED-based, approximately 100,000 hour lifetime. No external power is required. Typical scan time: ~2 s Connections:Wireless: Bluetooth Wired: USB What's included Go Direct SpectroVis Plus Spectrophotometer 15 plastic cuvettes and lids Mini USB Cable Power supply User Manual - GDX-SVISPL-INTL

CHF 1,037.70*
Go Direct® UV-VIS Spectrophotometer
The Go Direct® UV-VIS Spectrophotometer connects to your device via Bluetooth® wireless technology or USB to generate full spectra, Beer’s law data, and kinetic traces of ultraviolet and visible-absorbing samples (such as aspirin, DNA, proteins, and NADH). Specifications Detection modes: Absorbance, %Transmittance, Intensity, and Raw Lamp Experiment types: Full Spectrum, time-based (kinetics), and event-based (Beer’s law) Dimensions: 18.5 cm × 17.0 cm × 7.0 cm Lamp power supply: AC adapter (included) Bluetooth power supply: USB (USB power adapter included) Power consumption: 3 A start-up, 500 mA continuous Light source: Deuterium (UV) and incandescent (VIS) Detector: Linear CCD Wavelength range: 220–850 nm Wavelength reporting interval: ~1 nm Optical resolution: 3.0 nm (as determined with 486 nm hydrogen emission spectral line FWHM) Wavelength accuracy: ± 2.0 nm (as determined with holmium oxide NIST standard) Absorbance photometric accuracy: ± 5.0% (as determined with potassium dichromate NIST standards) Absorbance photometric range (for best accuracy): 0.1–1.0 Typical scan time: ~2 s Operating temperature: 15–35°C Sample format: 10 mm × 10 mm cuvette (two UV quartz cuvettes included) What's included Go Direct UV-VIS Spectrophotometer AC Power Supply Starna® quartz cuvettes (2) Mini USB cable USB Power Adapter User Manual - GDX-SPEC-UV-EURO

CHF 6,134.50*
Vernier Fluorescence / UV-VIS Spectrophotometer
The Go Direct Fluorescence/UV-Vis Spectrophotometer measures fluorescence and absorbance spectra of myriad samples, such as quinine sulfate, fluorescein, chlorophyll, and fluorescent proteins, all while connecting to your device via Bluetooth® wireless technology or USB. Specifications Detection modes: Absorbance, Fluorescence, %Transmittance, Intensity, and Raw Lamp Experiment types: Full Spectrum, time-based (kinetics), and event-based (Beer’s law) Dimensions: 18.5 cm × 17.0 cm × 7.0 cm Lamp power supply: AC adapter (included) Bluetooth power supply: USB (USB adapter Included) Power consumption: 3 A start-up, 500 mA continuous Absorbance light source: Deuterium (UV) and incandescent (VIS) Emission light source: Exchangeable LED (ships with 375 nm, 450 nm, and 525 nm) Detector: Linear CCD Wavelength range: 220–850 nm Wavelength reporting interval: ~1 nm Optical resolution: 3.0 nm (as determined with 486 nm hydrogen emission spectral line FWHM) Wavelength accuracy: ±2.0 nm (as determined with holmium oxide NIST standards) Absorbance photometric accuracy: ±5.0% (as determined with potassium dichromate NIST standards) Absorbance photometric range (for best accuracy): 0.1–1.0 Typical scan time: ~2 s Sample format: 10 mm × 10 mm cuvette (UV fluorescence cuvette included) Fluorescence emission detection limit: 1 mg/L quinine sulfate dihydrate in 0.1 M H2SO4 What's included Go Direct Fluorescence/UV-VIS Spectrophotometer AC Power Supply Fluorescence quartz cuvette Mini USB Cable USB Power Adapter LED cartridges (3): 375 nm, 450 nm, 525 nm User Manual - GDX-SPEC-FUV-EURO

CHF 7,255.80*
Skip product gallery

Similar Items

VSP Fluorescence LED Cartridges
For use with the Fluorescence/UV-VIS Spectrophotometer, this filter acts as an excitation source to cause the sample to fluoresce. Because the excitation source is an exchangeable LED, not only do you get the standard functionality of a spectrofluorometer but software controls allow students to determine the LED intensity and explore fluorescence as a function of excitation. Available LED Cartridges: VSP 280 nm LED VSP 350 nm LED VSP 375 nm LED VSP 400 nm LED VSP 450 nm LED VSP 500 nm LED VSP 525 nm LED

From CHF 210.50*
SpectroVis Optical Fiber
Use the SpectroVis Optical Fiber with SpectroVis Plus to measure light emissions of LEDs, fluorescent bulbs, or incandescent lights. For spectrum tube emissions, we recommend the Vernier Emissions Spectrometer (VSP-EM). Not compatible to GDX-SVISPL User manual

CHF 152.90*
Vernier Emissions Fiber
This fiber is an accessory for the Go Direct® Emissions Spectrometer and Vernier Emissions Spectrometer that allows for precise measurements of emissions spectrum wavelengths. This fiber can also be used with the Go Direct Visible Spectrophotometer, Vernier Spectrometer, and other Ocean Optics VIS-NIR Spectrometers. User Manual - VSP-EM-FIBER

CHF 222.20*