The BioChamber 250 is a 250 mL Nalgene bottle that can be used with a CO2 Gas Sensor and an O2 Gas Sensor to monitor gaseous carbon dioxide and oxygen levels simultaneously in a closed system.

User Manual - BC-250

Fach: Biology, Vernier, chemistry

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

O2 Gas Sensor
The O2 Gas Sensor can be used to monitor gaseous oxygen levels in a variety of biology and chemistry experiments. The sensor is intended for measuring gaseous, not aqueous, O2 concentration. Specifications Measurement Range: 0–27% (0-270 ppt) Accuracy (@ Standard Pressure 760 mm Hg): +/- 1% O2 Typical Resolution: 0.01% Response Time: 90% of final reading in ~12 seconds Warm-Up Time: Less than 5 seconds Pressure Effect: Directly proportional Vout = Vout (standard) x (P/1013) Pressure range: 0.5 atm to 1.5 atm Output Signal Range: 0.3 to 5 VDC; 2.7 to 3.8 VDC @ 21% O2 Output Impedance: 1 KΩ Input Voltage: 5 VDC +/–0.25 VDC Gas Sampling Mode: Diffusion Normal Operating Temperature Range: 20°C to 30°C Operating Temperature Range: 5 to 40°C (with calibration) Operating Humidity Range: 0 to 95% RH Storage Temperature Range: –20 to +60°C Dimensions: Sensor Tube: 45 mm length, 28 mm OD Total length: 135 mm What's included Vernier O2 Gas Sensor 250 mL gas sampling bottle User Manual - O2-BTA

CHF 489.20*
CO2 Gas Sensor
The CO2 Gas Sensor measures gaseous carbon dioxide in two ranges–0 to 10,000 ppm and 0 to 100,000 ppm. Specifications Response time: 95% of full-scale reading in 120 seconds Warm-up time: 90 seconds Pressure effect: 0.19% of reading/mm of Hg from standard pressure Input potential: 5 V (±0.25V) Gas sampling mode: diffusion Normal operating temperature range: 25°C (±5°C) Operating humidity range: 5–95% (non-condensing) Storage temperature range: –40 to 65°C Measurement Range:Low range: 0 to 10,000 ppm CO2 High range: 0 to 100,000 ppm CO2 Typical Accuracy (at standard pressure, 1 atm):Low range:0 to 1,000 ppm: ±100 ppm 1,000 to 10,000 ppm: ±10% of reading High range:0 to 100,000 ppm: ±20% of reading Resolution:0 to 10,000 ppm CO2: 3ppm 0 to 100,000 ppm CO2: 30ppm What's included Vernier CO2 Gas Sensor 250 mL gas sampling bottle (Nalgene bottle with lid) User Manual - CO2-BTA

CHF 650.30*
Skip product gallery

Similar Items