Skip to main content Skip to search Skip to main navigation

Gas Pressure Sensor

Product information "Gas Pressure Sensor"

Use the Gas Pressure Sensor to monitor pressure changes of a gas in chemistry and biology experiments.

Specifications

  • Pressure Range: 0 to 210 kPa (0 to 2.1 atm or 0 to 1600 mm Hg)
  • Accuracy: ±4 kPa
  • Maximum pressure that the sensor can tolerate without permanent damage: 405 kPa (4 atm)

What's included

  • Vernier Gas Pressure Sensor
  • Tapered valve connectors (Stopper Stems)(2) inserted into a No. 5 stopper
  • Tapered valve connector (Stopper Stem)(1) inserted into a No. 1 stopper
  • Two-way valve
  • 18 inch Tygon tubing with Luer Lock connectors
  • 20 mL syringe
  • White transpiration tubing clamps (2)

User Manual - GPS-BTA

Bildungsstufe: Diploma/ Vocational/ Uni
Fach: Biology, Vernier, chemistry

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Gas Pressure Sensor Bulb - 4 Pack
An affordable, latex- and phthalate-free accessory, the Gas Pressure Sensor Bulb is designed to be used with the Gas Pressure Sensor to easily perform grip strength measurements. What's included Gas Pressure Sensor Bulb or Bulbs User Manual - GPS-BULB4

CHF 50.90*
TI-Innovator™ TI-SensorLink Adapter
Allows for connection to four popular Vernier sensors (pH, Temperature, Force, or Pressure sensors) to the TI-Innovator™ Hub. Designed to be used with the TI-Innovator™ Hub.

CHF 77.90*
TI Bluetooth® Adapter
The TI Bluetooth® adapter allows select Texas Instruments (TI) calculators to wirelessly connect to one of our six most popular Go Direct® sensors. Students can code beyond the screen of their TI calculator by integrating live sensor data into their Python® programming language activities. See Texas Instruments website for more information.TI Bluetooth Adaptor Settup GuideAdditional Resources from Texas InstrumentsSupported Calculators: TI-84 Plus CE (Python Edition) TI-Nspire CX II Handheld TI-Nspire CX II CAS Handheld Supported Go Direct® Sensors: Go Direct® Force and Acceleration Sensor* Go Direct® Light and Color Sensor* Go Direct® Motion Detector Go Direct® pH Sensor Go Direct® Gas Pressure Sensor Go Direct® Temperature Probe *This sensor has multiple sensor channels; however, the TI-84 Plus CE Python Edition calculator only supports one sensor channel at a time. The TI-Nspire CX II and TI-Nspire CX II CAS handhelds support up to four sensor channels at a time from this sensor.

CHF 52.00*
Stopper Stem
The Stopper Stem, or tapered valve connector, is a plastic Luer-Lock connector with a tapered, ribbed tip. When inserted into a stopper hole, it allows a Luer-Lock connection to the stopper. User Manual - PS-STEM

CHF 2.00*
Plastic 2-Way Valve
Plastic stopcock with Luer-Lock connections. Part of the Pressure Sensor Accessories Kit and a replacement part for the Drop Counter. User Manual - PS-2WAY

CHF 6.10*
Gas Pressure Sensor Replacement Parts
This kit is included with the Gas Pressure Sensor. It contains all accessories for performing chemistry and biology experiments using any of the Vernier pressure sensors. User Manual - PS-ACC

CHF 30.50*
Chemistry with Vernier
Chemistry with Vernier is the foundational chemistry book for high school and college courses. Chemistry with Vernier has more than 36 experiments in thermochemistry, gas laws, acid-base reactions, equilibrium, electrochemistry, electrolytes, states of matter, and more. Experiments are included for the Gas Pressure Sensor, Temperature Probe, pH Sensor, Conductivity Probe, Colorimeter, and Voltage Probe. If you teach Advanced Placement (AP), International Baccalaureate (IB), or college chemistry, you should also consider Advanced Chemistry with Vernier (CHEM-A) and Investigating Chemistry through Inquiry (CHEM-I).

From CHF 83.40*
Plastic Syringe - 10 Pack
20 mL plastic syringe with Luer-Lock connector. Part of the Gas Pressure Sensor Replacement Parts. You can also buy the syringes in a 10 pack. User Manual - PS-SYR10

Content: 10 Paket(e) (CHF 3.87* / 1 Paket(e))

CHF 38.70*
Vernier Coding Activities with Arduino®: Analog Sensors
Students get excited when they see coding come to life through hands-on digital technology. Integrating Vernier LabQuest® sensor technology with Arduino microcontrollers connects the physical world to the computer-centric activity of learning to code. The Vernier Coding Activities with Arduino: Analog Sensors e-book is included with the purchase of the Vernier Arduino Interface Shield. User Manual - VCA-AS-E

CHF 44.40*
Luer-Lock Connector
Small connector that fits in the end of the plastic tubing and allows a Luer-Lock connection. Part of the Pressure Sensor Accessories Kit. User Manual - PS-LUER

CHF 2.00*
Plastic Tubing
More of the same tubing included with the Pressure Sensor Accessories Kit. User Manual - PS-TUBING

CHF 2.00*
Plastic Syringe - Single Unit
20 mL plastic syringe with Luer-Lock connector. Part of the Gas Pressure Sensor Replacement Parts. You can also buy the syringes in a 10 pack. User Manual - PS-SYR

CHF 4.00*
Respiration Monitor Belt
The Respiration Monitor Belt is used to measure human respiration rates. The Respiration Monitor Belt is used with the Gas Pressure Sensor (GPS-BTA) to measure human respiration. Simply strap the belt around the chest and pump air into the belt with the hand bulb, and monitor the pressure associated with the expansion and contraction of the chest during breathing. User manual

CHF 122.50*
Skip product gallery

Similar Items

Go Direct™ Gas Pressure Sensor
The Go Direct Gas Pressure Sensor measures the absolute pressure of a gas. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range: 0 to 400 kPa Resolution: 0.03 kPa Accuracy: ±3 kPA Maximum sampling rate: 50 samples/s Internal volume: 0.8 mL Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa Connections:Wireless: Bluetooth Wired: USB What's included Vernier Go Direct Gas Pressure Sensor Tapered valve connectors (Stopper Stems)(2) inserted into a No. 5 stopper Tapered valve connector (Stopper Stem)(1) inserted into a No. 1 stopper Two-way valve 18 inch Tygon tubing with Luer Lock connectors 20 mL syringe White transpiration tubing clamps (2) User Manual - GDX-GP

CHF 242.60*
Pressure Sensor 400
The Pressure Sensor 400 will measure absolute pressures from 0 to 400 kPa. The sensor also operates with excellent accuracy over a wide temperature range. The robust metal fittings allow for a tight, leakproof seal to your reaction apparatus. An accessories kit is included with the sensor. Specifications Range: 0–400 kPa Sensing element: Honeywell PX2 Series Accuracy using factory calibration: ±2 kPa Accuracy using custom calibration: ±1 kPa (1 point calibration at atmosphere) Temperature range: –40°C to 125°C Max pressure without damage: 800 kPa What's included Vernier Pressure Sensor 400 Accessories kitDouble-barb brass connector to fit flexible tubing Nickel plated brass push-to-connect Connector to fit more rigid tubing Two-foot section of nylon tubing Two-foot section of plastic tubing Tightening wrenches and plumber’s tape to ensure a tight seal User Manual - PS400-BTA

CHF 540.20*
Plastic Syringe - 10 Pack
20 mL plastic syringe with Luer-Lock connector. Part of the Gas Pressure Sensor Replacement Parts. You can also buy the syringes in a 10 pack. User Manual - PS-SYR10

Content: 10 Paket(e) (CHF 3.87* / 1 Paket(e))

CHF 38.70*