The Go Direct Drop Counter precisely records the number of drops of titrant added during a titration and then automatically converts it to volume. It connects via Bluetooth® wireless technology or via USB to your device.

Specifications

  • Accurate drop counting at rates up to 6 drops/s
  • Dimensions:Opening for drops: 3 cm
  • Openings for sensors (diameter): 7 mm and 13 mm
  • Ring stand opening: 16 mm
  • Total length: 15.5 cm, width: 4.5 cm, height: 1.8 cm
  • Distance from center of ring stand opening to center of drop opening (ideal): 10.5 cm
  • Distance from center of ring stand opening to center of sensor opening (ideal): 12 cm
  • Connections:Wireless: Bluetooth
  • Wired: USB

What's included

  • Go Direct Drop Counter
  • Plastic reagent reservoir
  • Plastic valve with a double stopcock fitting
  • Vernier Microstirrer
  • Micro USB Cable

User Manual - GDX-DC

Betriebsystem: Android, Chrome, LabQuest 2, Mac OSX, Win, iOS
Bildungsstufe: Diploma/ Vocational/ Uni
DataLogger Schnittstellen: LabQuest
Fach: Vernier, chemistry
Hersteller: Vernier
Schnittstelle: BlueTooth, USB

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Advanced Chemistry with Vernier
Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor. ​Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments. Use it in addition to​ ​Vernier Chemistry Investigations for Use with AP Chemistry​ (APCHEM) ​for a comprehensive set of topics.​

From CHF 83.40*
Vernier Chemistry Investigations for Use with AP* Chemistry - Print and E-Book
This lab book provides AP* Chemistry students with 16 inquiry-based laboratory experiments aligned with the inquiry investigations published by the College Board. Each experiment guides students to investigate key principles of AP Chemistry using electronic sensors to collect important data. User Manual - APCHEM

CHF 120.20*
Go Direct® 300 mAh Replacement Battery
The Go Direct® 300 mAh Replacement Battery is a rechargeable, lithium-polymer unit that comes with a one-year warranty. User Manual - GDX-BAT-300

CHF 22.40*
Stir Station
The Stir Station is a combination magnetic stirrer and ring stand. What's included Vernier Stir Station Vernier Microstirrer Stirring bar (4 cm) 6-volt DC power adapter Ring stand post (46 cm) User Manual - STIR-INTL

CHF 375.10*
Chemistry with Vernier
Chemistry with Vernier is the foundational chemistry book for high school and college courses. Chemistry with Vernier has more than 36 experiments in thermochemistry, gas laws, acid-base reactions, equilibrium, electrochemistry, electrolytes, states of matter, and more. Experiments are included for the Gas Pressure Sensor, Temperature Probe, pH Sensor, Conductivity Probe, Colorimeter, and Voltage Probe. If you teach Advanced Placement (AP), International Baccalaureate (IB), or college chemistry, you should also consider Advanced Chemistry with Vernier (CHEM-A) and Investigating Chemistry through Inquiry (CHEM-I).Table of ContentsExperimentSuggested Products1Endothermic and Exothermic ReactionsGo Direct® Temperature Probe2Freezing and Melting of WaterGo Direct® Temperature Probe3Another Look at Freezing TemperatureGo Direct® Temperature Probe (2)4Heat of Fusion for IceGo Direct® Temperature Probe5Find the Relationship: An Exercise in Graphing AnalysisNo probeware used6Boyle's Law: Pressure-Volume Relationship in GasesGo Direct® Gas Pressure Sensor7Pressure-Temperature Relationship in GasesGo Direct® Gas Pressure Sensor, Go Direct® Temperature Probe8Fractional DistillationGo Direct® Temperature Probe9Evaporation and Intermolecular AttractionsGo Direct® Temperature Probe (2)10Vapor Pressure of LiquidsGo Direct® Gas Pressure Sensor, Go Direct® Temperature Probe11Determining the Concentration of a Solution: Beer's LawGo Direct® Colorimeter12Effect of Temperature on Solubility of a SaltGo Direct® Temperature Probe13Properties of Solutions: Electrolytes and Non-ElectrolytesGo Direct® Conductivity Probe14Conductivity of Solutions: The Effect of ConcentrationGo Direct® Conductivity Probe15Using Freezing Point Depression to Find Molecular WeightGo Direct® Temperature Probe16Energy Content of FoodsGo Direct® Temperature Probe17Energy Content of FuelsGo Direct® Temperature Probe18Additivity of Heats of Reaction: Hess's LawGo Direct® Temperature Probe19Heat of Combustion: MagnesiumGo Direct® Temperature Probe20Chemical Equilibrium: Finding a Constant, KcGo Direct® Colorimeter21Household Acids and BasesGo Direct® pH Sensor22Acid RainGo Direct® pH Sensor23Titration Curves of Strong and Weak Acids and BasesGo Direct® pH Sensor24Acid-Base TitrationGo Direct® pH Sensor, Go Direct® Drop Counter, Precision Volume Dispenser25Titration of a Diprotic Acid: Identifying an UnknownGo Direct® pH Sensor, Go Direct® Drop Counter, Precision Volume Dispenser26Using Conductivity to Find an Equivalence PointGo Direct® Conductivity Probe, Go Direct® Drop Counter, Precision Volume Dispenser27Acid Dissociation Constant, KaGo Direct® pH Sensor28Establishing a Table of Reduction Potentials: Micro-Voltaic CellsGo Direct® Voltage Probe29Lead Storage BatteriesGo Direct® Voltage Probe30Rate Law Determination of the Crystal Violet ReactionGo Direct® Colorimeter31Time-Release Vitamin C TabletsGo Direct® pH Sensor32The Buffer in LemonadeGo Direct® pH Sensor33Determining the Free Chlorine Content of Swimming Pool WaterGo Direct® Colorimeter34Determining the Quantity of Iron in a Vitamin TabletGo Direct® Colorimeter35Determining the Phosphoric Acid Content in Soft DrinksGo Direct® pH Sensor36Microscale Acid-Base TitrationGo Direct® pH Sensor

From CHF 83.40*
Go Direct® Charge Station
The Go Direct® Charge Station is the perfect solution for charging your Go Direct Sensors. Each charge station has sixteen charging ports—eight USB and eight wand-style sensor ports. LED lights on the Go Direct sensors will show charging status. The Go Direct Charge Station is also compatible with Go Wireless devices. USB cables not included. User Manual - GDX-CRG-EURO

CHF 232.40*
Skip product gallery

Similar Items

Drop Counter
Use the Drop Counter to perform accurate, automatic titrations. Record the number of drops or calibrate the drop size to record volume of titrant added during a titration. What's included Vernier Drop Counter Plastic reagent reservoir Plastic valve with a double stopcock fitting Vernier Microstirrer User Manual - VDC-BTD

CHF 265.00*