The Go Direct Temperature Probe is a rugged, general-purpose sensor that students can use to monitor temperature. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct Temperature Teacher Pack, which includes 8 Go Direct Temperature Probes and a Go Direct® Charge Station.
Specifications
Range: –40 to 125°C
Handle range: –10 to 45°C
Resolution: 0.01°C
Accuracy: ±0.25°C
Response time (time for 90% of reading): 20 seconds (in water, with stirring)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Temperature
Go Direct Temperature Probe
Micro USB Cable
Quick-start guide
Go Direct Temperature Teacher Pack
8 Go Direct Temperature Probes
Charge Station
8 Micro USB Cables
Quick-start guide
User Manual - GDX-TMP
Perfect for AP Chemistry and college general chemistry, Go Direct Platinum-Cell Conductivity provides an accurate and easy measurement of a solution’s conductivity or its total ion concentration. The platinum-cell sensing element provides high accuracy and chemical compatibility when measuring non-aqueous solutions, strong acids, and strong bases. This probe connects via Bluetooth® wireless technology or via USB to your device.
What's included
Go Direct Platinum-Cell Conductivity Probe
Micro USB Cable
User Manual - GDX-CONPT
The Go Direct Conductivity Probe determines the ionic content of an aqueous solution by measuring its electrical conductivity. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS)
Accuracy using factory calibration: ±1% of full scale reading (valid for 1 to 10,000 µS/cm)
Temperature compensation: Automatic from 5 to 35°C, can be turned off
Temperature range (can be placed in): 0 to 80°C
Cell constant: 1.0 cm-1
Resolution: 0.01 µS/cm
Description: ABS body, parallel carbon (graphite) electrodes
Dimensions: 12 mm OD and 12 cm length
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Conductivity Probe
Micro USB Cable
User Manual - GDX-CON
The Go Direct Ion-Selective Electrode Amplifier is a mV and mg/L amplifier that connects to Vernier Ion-Selective Electrodes and compatible third-party BNC ion-selective electrodes. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Units: mV or mg/L
Input range (mV): ±1000 mV
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Ion-Selective Electrode Amplifier
Micro USB Cable
User Manual - GDX-ISEA
The Go Direct Electrode Amplifier is a mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Units: pH or mV
Input range (mV): ±1000 mV
Input range (pH): 0 to 14 pH
Accuracy with new electrode (mV): ±20 mV
Accuracy with new electrode (pH): ±0.2
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Electrode Amplifier
Micro USB Cable
User Manual - GDX-EA
Collect data on forces developed during stepping, jumping, and other human-scale actions.
Specifications
Force range: –350 to +3500 N
Maximum non-damaging force: 4500 N (1000 lb) compression
Typical resolution: 1 N
Dimensions: 31.5 cm x 31.5 cm x 3.5 cm
What's included
Go Direct Force Plate
Micro USB Cable
(1) Pair of handles
(4) Feet
(4) Thumbscrews for securing handles.
Note: Handles can be attached to the back side of the force plate. Do not step on the force plate when the handles are attached.
User Manual - GDX-FP
Use the Go Direct 2-Axis Force Plate to measure both the lateral and normal forces developed during investigations involving friction, stepping, jumping, and other human-scale actions.
Specifications
Normal Force
Force range: –350 to +3500 N where positive value is a compression force
Maximum non-damaging force: 4500 N (1000 lbs) compression
Lateral Force
Force range: –2000 to +2000 N
Maximum non-damaging force: 2500 N (560 lbs)
Dimensions: 31.5 cm x 31.5 cm x 6.5 cm
What's included
Go Direct 2-Axis Force PlateGo Direct Force Plate
Lateral Force Accessory
BTA to BTA Short Cable
T25 Torx® Wrench
USB Cable (micro)
(2) Force Plate Handles (includes 4 screws)
(4) Force Plate Feet
User Manual - GDX-FP2D
This accessory can be combined with the Go Direct® Force Plate or the Force Plate to measure both normal and lateral forces developed during human-scale actions like stepping, jumping, and running.
Specifications
Force range: –2000 to +2000 N
Maximum non-damaging force: 2500 N (560 lbs)
Dimensions: 31.5 cm x 31.5 cm x 3.5 cm
What's included
Vernier Lateral Force Accessory
BTA to BTA Short Cable
BTA to BTA Long Cable
T25 Torx® Wrench
User Manual - 2D-FP
The Go Direct Gas Pressure Sensor measures the absolute pressure of a gas. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: 0 to 400 kPa
Resolution: 0.03 kPa
Accuracy: ±3 kPA
Maximum sampling rate: 50 samples/s
Internal volume: 0.8 mL
Maximum pressure that the sensor can tolerate without permanent damage: 450 kPa
Connections:Wireless: Bluetooth
Wired: USB
What's included
Vernier Go Direct Gas Pressure Sensor
Tapered valve connectors (Stopper Stems)(2) inserted into a No. 5 stopper
Tapered valve connector (Stopper Stem)(1) inserted into a No. 1 stopper
Two-way valve
18 inch Tygon tubing with Luer Lock connectors
20 mL syringe
White transpiration tubing clamps (2)
User Manual - GDX-GP
The Go Direct Motion Detector uses ultrasound to measure the position, velocity, and acceleration of moving objects. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: 15 cm to 3.5 m
Resolution: 1 mm
Maximum sampling rate: 30 samples/s
Accuracy: ≤±1.0% FS
Connections:Wireless: Bluetooth
Wired: USB
What's included
Vernier Go Direct Motion Detector
Micro USB Cable
User Manual - GDX-MD
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct pH Teacher Pack, which includes 8 Go Direct pH Sensors and a Go Direct® Charge Station.
Specifications
pH range: 0–14
Accuracy with new electrode (pH): ±0.2
Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
Shaft diameter: 12 mm OD
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct pH
Go Direct pH Sensor (includes Go Direct Electrode Amplifier)
pH storage solution bottle with pH storage solution
Micro USB Cable
Quick-start guide
Go Direct pH Teacher Pack
8 Go Direct pH Sensors
8 pH storage solution bottles with pH storage solution
Charge Station
8 Micro USB Cables
Quick-start guide
User Manual - GDX-PH
The Go Direct Radiation Monitor detects alpha, beta, gamma, and X-ray radiation. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Sensor: LND 712 (or equivalent) halogen-quenched GM tube with a mica end window, 1.5 to 2.0 mg/cm2 thick
Sensitive to alpha, beta, gamma, and X-ray radiation
Powered by rechargeable 300 mAh battery, recharged via USB cable
Red LED blinks on radiation detection
Optional audio signal on radiation detection
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Radiation Monitor
Micro USB Cable
User Manual - GDX-RAD
The Go Direct Respiration Belt measures human respiration rate. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: 0–50 N
Resolution: 0.01 N
Response time: 50 ms
Respiration rate calculation:Sample window: 30 s
Advance interval: 10 s
Step rate calculation:Sample window: 10 s
Advance interval: 10 s
Maximum chest circumference: 140 cm
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Respiration Belt
Micro USB Cable
User Manual - GDX-RB
The Go Direct 3-Axis Magnetic Field Sensor allows you to determine the magnitude and direction of the magnetic field at any point in space. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Measurement range: ±5 mT and ±130 mT
Operating temperature: –40°C to 85°C
Resolution: 0.01 mT or better
Dimensions: 19 cm long, wand portion 12.2 cm long. Wand tapers from 0.8 cm square at handle to 0.7 cm square at tip. Designed to be placed inside a solenoid if needed.
Calibration: Factory-calibrated, user does not need to calibrate.
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct 3-Axis Magnetic Field Sensor
Micro USB Cable
User Manual - GDX-3MG
Connect the Go Direct® Nitrate Ion-Selective Electrode BNC to our Go Direct® Ion-Selective Electrode Amplifier to measure the potential (mV) and calculate the concentration of nitrate (NO3-) ions in aqueous samples.
Specifications
Range (mV):Go Direct® Ion-Selective Electrode Amplifier: -1000 mV to +1000 mV
Range (concentration): 1 to 14,000 mg/L (or ppm)
Reproducibility (precision): ±30mV
Interfering ions: ClO4–, I–, ClO3–, F–
pH range: 2.5–11 (no pH compensation)
Temperature range: 0–40°C (no temperature compensation)
Electrode slope: -55 ±3 mV/decade at 25°C
Electrode resistance: 0.1 to 5 MΩ
Minimum sample size: must be submerged 2.8 cm (1.1 in)
What's included
Go Direct Nitrate Ion-Selective Electrode with BNC terminated end, packed with a storage bottle
30 mL bottle of High Standard solution with SDS (1000 mg/L NO3–)
30 mL bottle of Low Standard solution with SDS (10 mg/L NO3–)
Short-Term ISE Soaking Bottle
User Manual - GDX-NO3-BNC
The 4-wavelength Go Direct Colorimeter measures absorbance or transmittance of a liquid sample. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: 0 to 3 (absorbance)
Useful range:0.05 to 1.0 (absorbance)
90% to 10% transmittance (%T)
Wavelengths: 430 nm, 470 nm, 565 nm, 635 nm
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Colorimeter
Micro USB Cable
3.5 mL cuvettes (15)
User Manual - GDX-COL
The Go Direct Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range (mV): ±1000 mV
Range (concentration): 1 to 18,000 mg/L (or ppm)
Accuracy: ±10% of full scale (calibrated 1 to 100 mg/L)
Interfering ions: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+
pH range: 2–7 (no pH compensation)
Temperature range: 0–40°C (no temperature compensation)
Electrode slope: 55 ±3 mV/decade at 25°C
Electrode resistance: 0.1 to 5 MΩ
Minimum sample size: must be submerged 2.8 cm (1.1 in)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct ISE Amplifier attached to a Go Direct Ammonium Ion-Selective Electrode BNC
Micro USB cable
30 mL bottle of High Standard solution with SDS (100 mg/L or 100 ppm NH4+ as N)
30 mL bottle of Low Standard solution with SDS (1 mg/L or 1 ppm NH4+ as N)
Short-Term ISE Soaking Bottle
User Manual - GDX-NH4
The Go Direct Drop Counter precisely records the number of drops of titrant added during a titration and then automatically converts it to volume. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Accurate drop counting at rates up to 6 drops/s
Dimensions:Opening for drops: 3 cm
Openings for sensors (diameter): 7 mm and 13 mm
Ring stand opening: 16 mm
Total length: 15.5 cm, width: 4.5 cm, height: 1.8 cm
Distance from center of ring stand opening to center of drop opening (ideal): 10.5 cm
Distance from center of ring stand opening to center of sensor opening (ideal): 12 cm
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Drop Counter
Plastic reagent reservoir
Plastic valve with a double stopcock fitting
Vernier Microstirrer
Micro USB Cable
User Manual - GDX-DC
The Precision Volume Dispenser offers highly accurate and controlled drop dispensing for automated titrations. When paired with a drop counter, it improves efficiency and precision, delivering consistent results with reduced errors compared to manual methods. This makes it ideal for streamlining titration experiments.
What's included
(1) Precision Volume Dispenser with stopcock and delivery tip connected
(1) Precision Volume Dispenser Clamp
User Manual - DC-DISP
The Go Direct Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of calcium (Ca2+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range (mV): ±1000 mV
Range (concentration): 1 to 40,000 mg/L (or ppm)
Accuracy: ±10% of full scale (calibrated 10 to 1000 mg/L)
Interfering ions: Pb2+, Hg2+, Si2+, Cu2+, Ni2+, NH3, Na+, Li+, K+, Ba2+, Zn2+, Mg2+
pH range: 2–8 (no pH compensation)
Temperature range: 0–40°C (no temperature compensation)
Electrode slope: 26 ±2 mV/decade at 25°C
Electrode resistance: 100 MΩ
Minimum sample size: must be submerged 2.8 cm (1.1 in)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct ISE Amplifier attached to a Go Direct Calcium Ion-Selective Electrode BNC
Micro USB cable
30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm Ca2+)
30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm Ca2+)
Short-Term ISE Soaking Bottle
User Manual - GDX-CA
The Go Direct Force and Acceleration Sensor couples a 3-axis accelerometer with a stable and accurate force sensor that measures forces as small as ±0.1 N and up to ±50 N. Measure pushes and pulls in the classroom or outdoors. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Force: ±50 N
Acceleration: 3 axis, ±16 g
Gyroscope: 3 axis, 2000°/s
Accuracy: ±0.2 N when calibrated
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Force and Acceleration Sensor
Hook
Bumper
Nylon screw
Accessory rod
Micro USB Cable
User Manual - GDX-FOR
The Go Direct Light and Color Sensor is a powerful and versatile light sensor that measures light in the visible to ultraviolet electromagnetic spectrum. An RGB color sensor detects relative contributions of primary colors in light. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Visible Light Sensor
Wavelengths: 400–800 nm
Range: 0 to 150,000 lux
Maximum sampling rate: 1,000 samples/s
UV Sensor
Responsive to UVB wavelengths
Maximum sampling rate: 1 Hz
RGB Sensor
Peak response: 615 nm peak (red); 525 nm peak (green); 465 nm peak (blue)
Maximum sampling rate: 0.5 Hz
What's included
Go Direct Light and Color Sensor
Micro USB Cable
User Manual - GDX-LC
The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
ORP Electrode
Accuracy: ±2% FS
Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
ORP element: 99% pure platinum band sealed on a glass stem
Shaft diameter: 12 mm OD
Impedance: ~20 kΩ at 25ºC
Electrode Amplifier
Units: mV
Input range: ±1000 mV
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct ORP (includes Go Direct Electrode Amplifier)
Micro USB Cable
pH storage solution bottle with pH Storage Solution
User Manual - GDX-ORP
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct pH Teacher Pack, which includes 8 Go Direct pH Sensors and a Go Direct® Charge Station.
Specifications
pH range: 0–14
Accuracy with new electrode (pH): ±0.2
Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
Shaft diameter: 12 mm OD
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct pH
Go Direct pH Sensor (includes Go Direct Electrode Amplifier)
pH storage solution bottle with pH storage solution
Micro USB Cable
Quick-start guide
Go Direct pH Teacher Pack
8 Go Direct pH Sensors
8 pH storage solution bottles with pH storage solution
Charge Station
8 Micro USB Cables
Quick-start guide
User Manual - GDX-PH-TP-INTL
The Go Direct Voltage Probe combines a wide input voltage range and high precision, making it an excellent choice for investigations of both AC/DC circuits and electromagnetism. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Differential input voltage range: 20 V
Maximum voltage on any input: 24 V
Typical resolution: 5 mV on Potential – 20 V channel
Maximum sampling rate: 1,000 samples/s
Accuracy: ≤±1.0% FS
Power: Internal rechargeable battery or USB connection
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Voltage Probe
Micro USB Cable
User Manual - GDX-VOLT
The Go Direct Current Probe measures the electric currents in circuits. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Range: +/- 1 A and +/- 0.1 A
Maximum non-damaging current: 1.5 A and 0.5 A
Typical resolution: 0.031 mA and 0.003 mA
Connections:Wireless: Bluetooth
Wired: USB
What's included
Vernier Go Direct Current Probe
Micro USB Cable
User Manual - GDX-CUR