Product information "Go Direct® Glass-Body pH Sensor"
Use the Go Direct Glass-Body pH to measure pH in aqueous, heterogeneous, and organic solutions. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
pH range: 0–14
Type: Glass shaft, sealed combination electrode with Ag/AgCl reference
Accuracy±0.2 pH units (factory calibration)
±0.05 pH units (user calibration)
Shaft diameter: 12 mm OD
Shaft material: glass
What's included
Go Direct Glass-Body pH Electrode BNC
Go Direct Electrode Amplifier
Electrode tip guard
pH storage solution bottle with pH Storage Solution
Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp.
What's included
Electrode Support
User Manual - ESUP
Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor.
Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments.
Use it in addition to Vernier Chemistry Investigations for Use with AP Chemistry (APCHEM) for a comprehensive set of topics.
Chemistry with Vernier is the foundational chemistry book for high school and college courses.
Chemistry with Vernier has more than 36 experiments in thermochemistry, gas laws, acid-base reactions, equilibrium, electrochemistry, electrolytes, states of matter, and more. Experiments are included for the Gas Pressure Sensor, Temperature Probe, pH Sensor, Conductivity Probe, Colorimeter, and Voltage Probe.
If you teach Advanced Placement (AP), International Baccalaureate (IB), or college chemistry, you should also consider Advanced Chemistry with Vernier (CHEM-A) and Investigating Chemistry through Inquiry (CHEM-I).Table of ContentsExperimentSuggested Products1Endothermic and Exothermic ReactionsGo Direct® Temperature Probe2Freezing and Melting of WaterGo Direct® Temperature Probe3Another Look at Freezing TemperatureGo Direct® Temperature Probe (2)4Heat of Fusion for IceGo Direct® Temperature Probe5Find the Relationship: An Exercise in Graphing AnalysisNo probeware used6Boyle's Law: Pressure-Volume Relationship in GasesGo Direct® Gas Pressure Sensor7Pressure-Temperature Relationship in GasesGo Direct® Gas Pressure Sensor, Go Direct® Temperature Probe8Fractional DistillationGo Direct® Temperature Probe9Evaporation and Intermolecular AttractionsGo Direct® Temperature Probe (2)10Vapor Pressure of LiquidsGo Direct® Gas Pressure Sensor, Go Direct® Temperature Probe11Determining the Concentration of a Solution: Beer's LawGo Direct® Colorimeter12Effect of Temperature on Solubility of a SaltGo Direct® Temperature Probe13Properties of Solutions: Electrolytes and Non-ElectrolytesGo Direct® Conductivity Probe14Conductivity of Solutions: The Effect of ConcentrationGo Direct® Conductivity Probe15Using Freezing Point Depression to Find Molecular WeightGo Direct® Temperature Probe16Energy Content of FoodsGo Direct® Temperature Probe17Energy Content of FuelsGo Direct® Temperature Probe18Additivity of Heats of Reaction: Hess's LawGo Direct® Temperature Probe19Heat of Combustion: MagnesiumGo Direct® Temperature Probe20Chemical Equilibrium: Finding a Constant, KcGo Direct® Colorimeter21Household Acids and BasesGo Direct® pH Sensor22Acid RainGo Direct® pH Sensor23Titration Curves of Strong and Weak Acids and BasesGo Direct® pH Sensor24Acid-Base TitrationGo Direct® pH Sensor, Go Direct® Drop Counter, Precision Volume Dispenser25Titration of a Diprotic Acid: Identifying an UnknownGo Direct® pH Sensor, Go Direct® Drop Counter, Precision Volume Dispenser26Using Conductivity to Find an Equivalence PointGo Direct® Conductivity Probe, Go Direct® Drop Counter, Precision Volume Dispenser27Acid Dissociation Constant, KaGo Direct® pH Sensor28Establishing a Table of Reduction Potentials: Micro-Voltaic CellsGo Direct® Voltage Probe29Lead Storage BatteriesGo Direct® Voltage Probe30Rate Law Determination of the Crystal Violet ReactionGo Direct® Colorimeter31Time-Release Vitamin C TabletsGo Direct® pH Sensor32The Buffer in LemonadeGo Direct® pH Sensor33Determining the Free Chlorine Content of Swimming Pool WaterGo Direct® Colorimeter34Determining the Quantity of Iron in a Vitamin TabletGo Direct® Colorimeter35Determining the Phosphoric Acid Content in Soft DrinksGo Direct® pH Sensor36Microscale Acid-Base TitrationGo Direct® pH Sensor
The Go Direct Electrode Amplifier is a mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes. It connects via Bluetooth® wireless technology or via USB to your device.
Specifications
Units: pH or mV
Input range (mV): ±1000 mV
Input range (pH): 0 to 14 pH
Accuracy with new electrode (mV): ±20 mV
Accuracy with new electrode (pH): ±0.2
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct Electrode Amplifier
Micro USB Cable
User Manual - GDX-EA
The Go Direct® Charge Station is the perfect solution for charging your Go Direct Sensors. Each charge station has sixteen charging ports—eight USB and eight wand-style sensor ports. LED lights on the Go Direct sensors will show charging status. The Go Direct Charge Station is also compatible with Go Wireless devices. USB cables not included.
User Manual - GDX-CRG-EURO
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct pH Teacher Pack, which includes 8 Go Direct pH Sensors and a Go Direct® Charge Station.
Specifications
pH range: 0–14
Accuracy with new electrode (pH): ±0.2
Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
Shaft diameter: 12 mm OD
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Connections:Wireless: Bluetooth
Wired: USB
What's included
Go Direct pH
Go Direct pH Sensor (includes Go Direct Electrode Amplifier)
pH storage solution bottle with pH storage solution
Micro USB Cable
Quick-start guide
Go Direct pH Teacher Pack
8 Go Direct pH Sensors
8 pH storage solution bottles with pH storage solution
Charge Station
8 Micro USB Cables
Quick-start guide
User Manual - GDX-PH
Our general-purpose pH Sensor can be used across disciplines, including chemistry, biology, middle school science, and environmental science.
Specifications
Range: pH 0–14
Accuracy with new electrode (pH): ±0.2
Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
Shaft Diameter: 12 mm OD
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
What's included
Vernier pH Sensor
pH storage solution
pH storage solution bottle
User Manual - PH-BTA
The Oxidation-Reduction Potential (ORP) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. Use the ORP Sensor to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction.
Specifications
Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference
Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Cable: 1 meter coaxial cable with BNC connector
Redox potential range: -450 to +1100 mV
ORP element: 99% pure platinum band sealed on a glass stem
Temperature range: 0-60ºC
Probe dimensions: 12 mm OD
Impedance: ~20 kΩ at 25ºC
What's included
ORP Electrode BNC
Electrode Amplifier
pH storage solution
User Manual - ORP-BTA
Use the Tris-Compatible Flat pH Sensor to measure the pH of a solution or semisolid, such as food or soil.
Specifications
Range: pH 0–14 (Some sodium error in ranges greater than pH 12 due to thicker glass and higher impedance values)
Electrode type: Double-junction, sealed, gel-filled, Ag/AgCl reference, polycarbonate body
Membrane style: Flat glass
Storage solution: pH 4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
Cable: 1 meter coaxial cable with BNC connector
What's included
Tris-Compatible Flat pH Electrode BNC
Electrode Amplifier
pH Storage Solution
User Manual - FPH-BTA
CHF 366.90*