Skip to main content Skip to search Skip to main navigation

Electrode Support

Product information "Electrode Support"

Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp.

What's included

Electrode Support

User Manual - ESUP

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

ORP Sensor
The Oxidation-Reduction Potential (ORP) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. Use the ORP Sensor to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction. Specifications Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Cable: 1 meter coaxial cable with BNC connector Redox potential range: -450 to +1100 mV ORP element: 99% pure platinum band sealed on a glass stem Temperature range: 0-60ºC Probe dimensions: 12 mm OD Impedance: ~20 kΩ at 25ºC What's included ORP Electrode BNC Electrode Amplifier pH storage solution User Manual - ORP-BTA

CHF 285.40*
Go Direct® Potassium Ion-Selective Electrode
The Go Direct Potassium Ion-Selective Electrode (ISE) can be used to measure the concentration of potassium (K+) ions in aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 39,000 mg/L (or ppm) Accuracy: ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 56 ±3 mV/decade at 25°C Electrode resistance: 100 to 200 kΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Potassium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm K+) Short-Term ISE Soaking Bottle User Manual - GDX-K

CHF 703.30*
Microstirrer
This is a replacement for the Microstirrer that ships with our Drop Counters. It takes the place of a magnetic stir bar but it attaches directly to the end of a pH sensor, or similar 12 mm OD sensor. The Microstirrer results in enhanced stirring near the electrode tip. User Manual - MSTIR

CHF 18.30*
Chloride Ion-Selective Electrode
The Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of Chloride (Cl-) in aqueous samples. Specifications Range (concentration): 1 to 35,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: CN–, Br–, I–, OH–, S2–, NH3 pH range: 2–12 (no pH compensation) Temperature range: 0–80°C (no temperature compensation) Electrode slope: –56 ±3 mV/decade at 25°C Electrode resistance: 1 to 5 MΩ Immersion: 2.8 cm Electrode length: 125 mm Body diameter: 12 mm Cable length: 100 cm What's included Vernier Chloride Ion-Selective Electrode 30 mL bottle of Chloride Low Standard (10 mg/L or 10 ppm Cl–) 30 mL bottle of Chloride High Standard (1000 mg/L or 1000 ppm Cl–) Short-term ISE soaking bottle Polishing Strips User Manual - CL-BTA

CHF 672.70*
Nitrate Ion-Selective Electrode
The Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples. Specifications Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: CIO4–, I–, ClO3–, CN–, BF4– pH range: 2–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Nitrate Ion-Selective Electrode 30 mL bottle of Nitrate Low Standard (1 mg/L or 1 ppm NO3–) 30 mL bottle of Nitrate High Standard (100 mg/L or 100 ppm NO3–) Short-term ISE soaking bottle User Manual - NO3-BTA

CHF 713.50*
Potassium Ion-Selective Electrode
The Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions. Specifications Range (concentration): 1 to 39,000 mg/L (or ppm) Reproducibility (precision): ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–10 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Potassium Ion-Selective Electrode 30 mL bottle of High Standard Standard (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard Standard (10 mg/L or 10 ppm K+) ISE soaking bottle (empty bottle with insertion cap) User Manual - K-BTA

CHF 705.30*
EasyTemp
The Vernier EasyTemp is a rugged, general-purpose temperature sensor for TI-84 Plus calculators and TI-Nspire handhelds. Specifications Temperature range: –20 to 115°C Maximum temperature that the sensor can tolerate without damage: 150°C Resolution: 0.07°C Accuracy: ±0.5°C Response time: 4 s (to 90% of full reading in water) What's included Vernier EasyTemp sensor User Manual - EZ-TMP

CHF 112.10*
Go Direct™ Electrode Amplifier
The Go Direct Electrode Amplifier is a mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Units: pH or mV Input range (mV): ±1000 mV Input range (pH): 0 to 14 pH Accuracy with new electrode (mV): ±20 mV Accuracy with new electrode (pH): ±0.2 Connections:Wireless: Bluetooth Wired: USB What's included Go Direct Electrode Amplifier Micro USB Cable User Manual - GDX-EA

CHF 181.40*
Conductivity Probe
The Conductivity Probe determines the ionic content of an aqueous solution by measuring its conductivity. This has many applications in chemistry, biology, and environmental science. Specifications Range:Low Range: 0 to 200 μS/cm (0 to 100 mg/L TDS) Mid Range: 0 to 2000 μS/cm (0 to 1000 mg/L TDS) High Range: 0 to 20,000 μS/cm (0 to 10,000 mg/L TDS) Typical Resolution:Low Range: 0.1 μS/cm (0.05 mg/L TDS) Mid Range: 1 μS/cm (0.5 mg/L TDS) High Range 10 μS/cm (5 mg/L TDS) Accuracy using factory calibration:±8% of full-scale reading for low range ±3% of full-scale reading for mid range ±4% of full-scale reading for high range Accuracy using custom calibration: ±2% of full-scale reading for each range Response Time: 98% of full-scale reading in 5 seconds, 100% of full-scale in 15 seconds Temperature Compensation: automatic from 5 to 35 °C Temperature Range (can be placed in): 0 to 80 °C Cell Constant: 1.0 cm-1 Description: ABS body, parallel carbon (graphite) electrodes Dimensions: 12 mm OD and 150 mm length What's included Vernier Conductivity Probe 90 mL bottle of 1000 µS/cm NaCl standard solution User Manual - CON-BTA

CHF 297.60*
Go Direct™ pH Sensor
The Go Direct pH Sensor is a general-purpose pH sensor used to monitor pH of aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct pH Teacher Pack, which includes 8 Go Direct pH Sensors and a Go Direct® Charge Station. Specifications pH range: 0–14 Accuracy with new electrode (pH): ±0.2 Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Shaft diameter: 12 mm OD Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct pH Go Direct pH Sensor (includes Go Direct Electrode Amplifier) pH storage solution bottle with pH storage solution Micro USB Cable Quick-start guide Go Direct pH Teacher Pack 8 Go Direct pH Sensors 8 pH storage solution bottles with pH storage solution Charge Station 8 Micro USB Cables Quick-start guide User Manual - GDX-PH

CHF 242.60*
Tris-Compatible Flat pH Sensor
Use the Tris-Compatible Flat pH Sensor to measure the pH of a solution or semisolid, such as food or soil. Specifications Range: pH 0–14 (Some sodium error in ranges greater than pH 12 due to thicker glass and higher impedance values) Electrode type: Double-junction, sealed, gel-filled, Ag/AgCl reference, polycarbonate body Membrane style: Flat glass Storage solution: pH 4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Cable: 1 meter coaxial cable with BNC connector What's included Tris-Compatible Flat pH Electrode BNC Electrode Amplifier pH Storage Solution User Manual - FPH-BTA

CHF 366.90*
Go Direct® Ethanol Vapor Sensor
Measure the concentration of ethanol in air above an aqueous sample with Go Direct Ethanol Vapor. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range: 0% to 3% Response Time: 90% of full scale in 60 seconds ConnectionsWireless: Bluetooth Wired: USB What's included Go Direct Ethanol Vapor Sensor Micro USB Cable 250 mL Nalgene Bottle w/Lid Ethanol Cap Assemblies Tape for Ethanol Sensor #6 Stopper for Ethanol Sensor User Manual - GDX-ETOH

CHF 385.30*
Stainless Steel Temperature Probe
The Stainless Steel Temperature Probe is a rugged, general-purpose temperature sensor that can be used in organic liquids, salt solutions, acids, and bases. Use it as you would use a thermometer for experiments in chemistry, physics, biology, Earth science, and environmental science. Specifications Temperature range: –40 to 135°C (–40 to 275°F) Maximum temperature that the sensor can tolerate without damage: 150°C Typical Resolution:0.17°C (–40 to 0°C) 0.03°C (0 to 40°C) 0.1°C (40 to 100°C) 0.25°C (100 to 135°C) Temperature sensor: 20 kΩ NTC Thermistor Accuracy: ±0.2°C at 0°C, ±0.5°C at 100°C Response time (time for 90% change in reading):10 seconds (in water, with stirring) 400 seconds (in still air) 90 seconds (in moving air) Probe dimensions:Probe length (handle plus body): 15.5 cm Stainless steel body: length 10.5 cm, diameter 4.0 mm Probe handle: length 5.0 cm, diameter 1.25 cm What's included Vernier Stainless Steel Temperature Probe User Manual - TMP-BTA

CHF 87.60*
Stir Station
The Stir Station is a combination magnetic stirrer and ring stand. What's included Vernier Stir Station Vernier Microstirrer Stirring bar (4 cm) 6-volt DC power adapter Ring stand post (46 cm) User Manual - STIR-INTL

CHF 375.10*
Calcium Ion-Selective Electrode
The Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of Calcium (Ca2+) in aqueous samples. Specifications Range (concentration): 1 to 40,000 mg/L (or ppm) Reproducibility (precision): ± 10% of full scale (calibrated 10 to 1000 mg) Interfering Ions: Pb2+, Hg2+, Si2+, Fe2+, Cu2+, Ni2+, NH3, Na+, Tris+, Li+, K+, Ba2+, Zn2+, Mg2+ pH Range (concentration): 2–8 (no pH compensation) Temperature range: 0-40°C (no temperature compensation) Electrode Slope: +26 mV/decade at 25°C Electrode Resistance: 100 MΩ Immersion: 2.8 cm (1.1 in) Electrode length 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Calcium Ion-Selective Electrode 30 mL bottle of Calcium Low Standard (10 mg/L or 10 ppm Ca2+) 30 mL bottle of Calcium High Standard (1000 mg/L or 1000 ppm Ca2+) Short-term ISE soaking bottle User Manual - CA-BTA

CHF 713.50*
Constant Current System
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments. Specifications Range: 0-0.6 A Typical Resolution: 0.09 mA Linearity: 0.1% Supply voltage: 5 VDC Current in amperes:Slope: 0.145 A/V Intercept: 0 A What's included Vernier Constant Current System Power supply The power supply included is the same as the LabQuest power supply. User Manual - CCS-BTA-INTL

CHF 234.40*
Go!Temp - Single Sensor
Collect temperature data directly through the USB port of a computer or Chromebook. Save money when you purchase the Go!Temp Teacher Pack, which includes 8 Go!Temp USB temperature sensors. Specifications Range: -20°C – 115°C Maximum temperature that the sensor can tolerate without damage: 150°C Resolution: 0.07°C Accuracy: ± 0.5°C Response Time: 4s (to 90% of full reading in water) What's included Go!Temp Go!Temp USB temperature probe Go!Temp Teacher Pack 8 Go!Temp USB temperature probes User Manual - GO-TEMP

CHF 112.10*
Go Direct™ Constant Current System
The Go Direct Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range: 0 to 0.6 A Supply voltage: 5 VDC Connections:Wireless: Bluetooth Wired: USB What's included Vernier Go Direct Constant Current System Power Supply Micro USB Cable The power supply included is the same as the LabQuest Power Supply. User Manual - GDX-CCS-INTL

CHF 234.40*
Ammonium Ion-Selective Electrode
The Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of Ammonium (NH4+) in aqueous samples. Specifications Range (concentration): 1 to 18,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: K+, Li+, Na+, Cs+, Mg3+, Ca2+, Sr2+, Ba2+ pH range: 4–7.5 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Ammonium Ion-Selective Electrode 30 mL bottle of Ammonium Low Standard (1 mg/L or 1 ppm NH4+ as N) 30 mL bottle of Ammonium High Standard (100 mg/L or 100 ppm NH4+ as N) Short-term ISE soaking bottle User Manual - NH4-BTA

CHF 672.70*
Go Direct™ ORP Sensor
The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It connects via Bluetooth® wireless technology or via USB to your device. Specifications ORP Electrode Accuracy: ±2% FS Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Shaft diameter: 12 mm OD Impedance: ~20 kΩ at 25ºC Electrode Amplifier Units: mV Input range: ±1000 mV Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ORP (includes Go Direct Electrode Amplifier) Micro USB Cable pH storage solution bottle with pH Storage Solution User Manual - GDX-ORP

CHF 283.30*
pH Sensor
Our general-purpose pH Sensor can be used across disciplines, including chemistry, biology, middle school science, and environmental science. Specifications Range: pH 0–14 Accuracy with new electrode (pH): ±0.2 Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Shaft Diameter: 12 mm OD Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) What's included Vernier pH Sensor pH storage solution pH storage solution bottle User Manual - PH-BTA

CHF 254.80*
Go Direct® Glass-Body pH Sensor
Use the Go Direct Glass-Body pH to measure pH in aqueous, heterogeneous, and organic solutions. It connects via Bluetooth® wireless technology or via USB to your device. Specifications pH range: 0–14 Type: Glass shaft, sealed combination electrode with Ag/AgCl reference Accuracy±0.2 pH units (factory calibration) ±0.05 pH units (user calibration) Shaft diameter: 12 mm OD Shaft material: glass What's included Go Direct Glass-Body pH Electrode BNC Go Direct Electrode Amplifier Electrode tip guard pH storage solution bottle with pH Storage Solution Micro USB cable User Manual - GDX-GPH

CHF 344.50*
Skip product gallery

Similar Items

DO Calibration Solution
This is a replacement bottle of sodium sulfite, used for the zero dissolved oxygen calibration point. One bottle is included with the DO Probe.

CHF 9.80*
Primary Productivity Kit
This kit is an accessory for one of our most popular biology labs, Primary Productivity. The kit consists of a box of 7 plastic bottles, 7 rubber stoppers, and a set of screens. User Manual - PPK

CHF 112.10*
Membrane for DO Sensor
This is a replacement membrane cap for a Dissolved Oxygen Probe. The membranes on DO Probes have a limited lifespan, the duration of which varies with frequency and care of use. One extra membrane cap is included with the DO Sensor. User Manual - MEM

CHF 38.70*