Skip to main content Skip to search Skip to main navigation

Go Direct™ Radiation Monitor

Product information "Go Direct™ Radiation Monitor"

The Go Direct Radiation Monitor detects alpha, beta, gamma, and X-ray radiation. It connects via Bluetooth® wireless technology or via USB to your device.

Specifications

  • Sensor: LND 712 (or equivalent) halogen-quenched GM tube with a mica end window, 1.5 to 2.0 mg/cm2 thick
  • Sensitive to alpha, beta, gamma, and X-ray radiation
  • Powered by rechargeable 300 mAh battery, recharged via USB cable
  • Red LED blinks on radiation detection
  • Optional audio signal on radiation detection
  • Connections:Wireless: Bluetooth
  • Wired: USB

What's included

  • Go Direct Radiation Monitor
  • Micro USB Cable

User Manual - GDX-RAD

Betriebsystem: Android, Chrome, LabQuest 2, Mac OSX, Win, iOS
Bildungsstufe: Diploma/High School, Diploma/ Vocational/ Uni
DataLogger Schnittstellen: LabQuest
Fach: Vernier, chemistry, physics
Fachbereich: Chemie, Physik
Hersteller: Vernier
Schnittstelle: BlueTooth, USB

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Investigating Chemistry through Inquiry
The Investigating Chemistry through Inquiry lab book contains 25 inquiry-based chemistry investigations. The book is authored by two long-time chemistry teachers, Donald L. Volz and Ray Smola, who have enjoyed using the inquiry method in their own instruction. Each experiment includes a preliminary activity, teacher information, sample researchable questions, and sample data for those researchable questions. If you are new to inquiry-based instruction, the extensive Instructor Sections that are included with each investigation will help guide you through the inquiry-based style of chemistry instruction. Included with Investigating Chemistry through Inquiry  Electronic Version 25 inquiry-based, chemistry investigations Access to up-to-date versions of the experiments Essential teacher information for successful inquiry investigations Suggested researchable questions, sample data, and graphs A generous site license—buy one book and duplicate the labs for your class Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

From CHF 83.40*
Tip
Vernier Graphical Analysis™ Pro School Site License
With Graphical Analysis Pro, students can visualize scientific data collected from Vernier sensors—boosting their understanding and engagement using rich, real–time graphs. This-easy-to-use-app works on operating systems commonly found in the classroom. Graphical Analysis Pro also includes crucial features that promote three-dimensional learning, critical thinking, student collaboration, asynchronous instruction, and deeper analysis of experiment phenomena. Review the comparison table below to see what Graphical Analysis Pro can add to your classroom.  Data Collection Collect experiment data from multiple sensors simultaneously using a multiple-channel interface, such as LabQuest Stream® or multiple Go Direct® sensors. Data Visualization Help your students visualize experiment data—and increase comprehension and retention—with richly detailed, customizable graphing.         Graphical Analysis Pro Remote EducationData Sharing Boost your students’ understanding of complex science concepts with real-time data sharing. Seeing experiment data collected right before their eyes helps students connect abstract ideas to the real world. Videos Synced with Data Customize instruction and learning using your experiment videos synced with data. Your students can even upload and share their own videos.   Sample Experiments Access dozens of experiment videos synced with real data to support both remote and in-person learning. These sample experiments help your students experience an experiment, even when lab equipment is unavailable. You can also use sample experiments for pre-labs and differentiation of instruction. Advanced Data Analysis Give your students more options for deeper analysis with user-defined curve fits and calculated columns. These features provide equation and expression customizations directly in the app for immediate analysis.

From CHF 14.50*
Advanced Chemistry with Vernier
Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor. ​Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments. Use it in addition to​ ​Vernier Chemistry Investigations for Use with AP Chemistry​ (APCHEM) ​for a comprehensive set of topics.​

From CHF 83.40*
Go Direct® 300 mAh Replacement Battery
The Go Direct® 300 mAh Replacement Battery is a rechargeable, lithium-polymer unit that comes with a one-year warranty. User Manual - GDX-BAT-300

CHF 22.40*
Sensor Bracket for Go Direct®
This bracket fits most of our box-shaped Go Direct® sensors. Attach the bracket to our accessory rod or any tripod with a standard camera mount to hold a sensor still and stable for repetitive measurements. Specifications Threaded insert: ¼-20 (¼ inch diameter, 20 threads per inch) What's included 1 sensor bracket User Manual - GDX-MOUNT

CHF 12.20*
Skip product gallery

Similar Items

Vernier Radiation Monitor
The Vernier Radiation Monitor detects alpha, beta, gamma, and X-ray radiation. Applications include nuclear counting statistics, shielding, and decay rate measurements. Specifications Sensor: LND 712 (or equivalent) halogen-quenched GM tube with a mica end window, 1.5 to 2.0 mg/cm2 thick Sensitive to alpha, beta, gamma, and X-ray radiation Powered by interface connection Red LED blinks on radiation detection Optional audio signal on radiation detection What's included Vernier Radiation Monitor User Manual - VRM-BTD

CHF 509.60*