Skip to main content Skip to search Skip to main navigation

Standard Potassium Solution

Product information "Standard Potassium Solution"

The Low and High ISE standards are used to calibrate our Potassium Ion-Selective Electrodes.

User Manual - K-HST

Hersteller: Vernier

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Go Direct® Potassium Ion-Selective Electrode
The Go Direct Potassium Ion-Selective Electrode (ISE) can be used to measure the concentration of potassium (K+) ions in aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 39,000 mg/L (or ppm) Accuracy: ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 56 ±3 mV/decade at 25°C Electrode resistance: 100 to 200 kΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Potassium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm K+) Short-Term ISE Soaking Bottle User Manual - GDX-K

CHF 703.30*
Potassium Ion-Selective Electrode
The Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions. Specifications Range (concentration): 1 to 39,000 mg/L (or ppm) Reproducibility (precision): ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–10 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Potassium Ion-Selective Electrode 30 mL bottle of High Standard Standard (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard Standard (10 mg/L or 10 ppm K+) ISE soaking bottle (empty bottle with insertion cap) User Manual - K-BTA

CHF 705.30*
Standard Potassium Solution - Low
The Low and High ISE standards are used to calibrate our Potassium Ion-Selective Electrodes. User Manual - K-LST

CHF 59.10*
Skip product gallery

Similar Items

ISE Ammonium High Standard
The High and Low ISE standards are used to calibrate our Ammonium Ion-Selective Electrodes. User Manual - NH4-HST

CHF 59.10*
ISE Nitrate High Standard
The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes. User Manual - NO3-HST

CHF 59.10*