ISE Nitrate High Standard

Product information "ISE Nitrate High Standard"

The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes.

User Manual - NO3-HST

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

ISE Nitrate Replacement Module
This module replaces the PVC electrode in the Nitrate ISE. User Manual - NO3-MOD

CHF 193.20*
Nitrate Ion-Selective Electrode
Connect the Go Direct® Nitrate Ion-Selective Electrode BNC to our Go Direct® Ion-Selective Electrode Amplifier to measure the potential (mV) and calculate the concentration of nitrate (NO3-) ions in aqueous samples. Specifications Range (mV):Go Direct® Ion-Selective Electrode Amplifier: -1000 mV to +1000 mV Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±30mV Interfering ions: ClO4–, I–, ClO3–, F– pH range: 2.5–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) What's included Go Direct Nitrate Ion-Selective Electrode with BNC terminated end, packed with a storage bottle 30 mL bottle of High Standard solution with SDS (1000 mg/L NO3–) 30 mL bottle of Low Standard solution with SDS (10 mg/L NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NO3-BNC

CHF 548.40*
ISE Nitrate Low Standard
The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes. User Manual - NO3-LST

CHF 59.10*
Nitrate Ion-Selective Electrode
The Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples. Specifications Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: CIO4–, I–, ClO3–, CN–, BF4– pH range: 2–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Nitrate Ion-Selective Electrode 30 mL bottle of Nitrate Low Standard (1 mg/L or 1 ppm NO3–) 30 mL bottle of Nitrate High Standard (100 mg/L or 100 ppm NO3–) Short-term ISE soaking bottle User Manual - NO3-BTA

CHF 713.50*
Go Direct® Nitrate Ion-Selective Electrode
The Go Direct Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of nitrate (NO3-) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 14,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: ClO4–, I–, ClO3–, F– pH range: 2.5–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: –55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Nitrate Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (100 mg/L or 100 ppm NO3–) 30 mL bottle of Low Standard solution with SDS (1 mg/L or 1 ppm NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NO3

CHF 711.50*
Skip product gallery

Similar Items

ISE Ammonium High Standard
The High and Low ISE standards are used to calibrate our Ammonium Ion-Selective Electrodes. User Manual - NH4-HST

CHF 59.10*
Standard Potassium Solution
The Low and High ISE standards are used to calibrate our Potassium Ion-Selective Electrodes. User Manual - K-HST

CHF 59.10*
ISE Nitrate Low Standard
The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes. User Manual - NO3-LST

CHF 59.10*