Skip to main content Skip to search Skip to main navigation

Go Direct™ Electrode Amplifier

Product information "Go Direct™ Electrode Amplifier"

The Go Direct Ion-Selective Electrode Amplifier is a mV and mg/L amplifier that connects to Vernier Ion-Selective Electrodes and compatible third-party BNC ion-selective electrodes. It connects via Bluetooth® wireless technology or via USB to your device.

Specifications

  • Units: mV or mg/L
  • Input range (mV): ±1000 mV
  • Connections:Wireless: Bluetooth
  • Wired: USB

What's included

  • Go Direct Ion-Selective Electrode Amplifier
  • Micro USB Cable

User Manual - GDX-ISEA

Betriebsystem: Android, Chrome, LabQuest 2, Mac OSX, Win, iOS
Bildungsstufe: Diploma/High School, Diploma/ Vocational/ Uni, Middle years
DataLogger Schnittstellen: LabQuest
Fach: Biology, chemistry
Fachbereich: Biologie, Chemie
Hersteller: Vernier
Schnittstelle: BlueTooth, USB

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Go Direct® Ammonium Ion-Selective Electrode BNC
Connect the Go Direct®Ammonium Ion-Selective Electrode BNC to our Go Direct® Ion-Selective Electrode Amplifier to measure the potential (mV) and calculate the concentration of ammonium (NH4+) ions in aqueous samples. Specifications Range (mV):Electrode Amplifier: -450 mV to +1100 mV Go Direct® Electrode Amplifier: -1000 mV to +1000 mV Range (concentration): 1 to 18,000 mg/L (or ppm) Reproducibility (precision): ±30mV Interfering ions: K+, Li+, Na+, Cs+, Mg3+, Ca2+, Sr2+, Ba2+ pH range: 2–7 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) What's included Go Direct Nitrate Ion-Selective Electrode with BNC terminated end, packed with a storage bottle 30 mL bottle of High Standard solution with SDS (1000 mg/L NO3–) 30 mL bottle of Low Standard solution with SDS (10 mg/L NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NH4-BNC

CHF 548.40*
Nitrate Ion-Selective Electrode
Connect the Go Direct® Nitrate Ion-Selective Electrode BNC to our Go Direct® Ion-Selective Electrode Amplifier to measure the potential (mV) and calculate the concentration of nitrate (NO3-) ions in aqueous samples. Specifications Range (mV):Go Direct® Ion-Selective Electrode Amplifier: -1000 mV to +1000 mV Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±30mV Interfering ions: ClO4–, I–, ClO3–, F– pH range: 2.5–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) What's included Go Direct Nitrate Ion-Selective Electrode with BNC terminated end, packed with a storage bottle 30 mL bottle of High Standard solution with SDS (1000 mg/L NO3–) 30 mL bottle of Low Standard solution with SDS (10 mg/L NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NO3-BNC

CHF 548.40*
Go Direct® Nitrate Ion-Selective Electrode
The Go Direct Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of nitrate (NO3-) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 14,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: ClO4–, I–, ClO3–, F– pH range: 2.5–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: –55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Nitrate Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (100 mg/L or 100 ppm NO3–) 30 mL bottle of Low Standard solution with SDS (1 mg/L or 1 ppm NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NO3

CHF 711.50*
Go Direct® Potassium Ion-Selective Electrode
The Go Direct Potassium Ion-Selective Electrode (ISE) can be used to measure the concentration of potassium (K+) ions in aqueous solutions. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 39,000 mg/L (or ppm) Accuracy: ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 56 ±3 mV/decade at 25°C Electrode resistance: 100 to 200 kΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Potassium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm K+) Short-Term ISE Soaking Bottle User Manual - GDX-K

CHF 703.30*
Electrode Support
Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. What's included Electrode Support User Manual - ESUP

CHF 20.30*
Go Direct® 300 mAh Replacement Battery
The Go Direct® 300 mAh Replacement Battery is a rechargeable, lithium-polymer unit that comes with a one-year warranty. User Manual - GDX-BAT-300

CHF 22.40*
Go Direct® Charge Station
The Go Direct® Charge Station is the perfect solution for charging your Go Direct Sensors. Each charge station has sixteen charging ports—eight USB and eight wand-style sensor ports. LED lights on the Go Direct sensors will show charging status. The Go Direct Charge Station is also compatible with Go Wireless devices. USB cables not included. User Manual - GDX-CRG-EURO

CHF 232.40*
Go Direct® Calcium Ion-Selective Electrode
The Go Direct Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of calcium (Ca2+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 40,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Pb2+, Hg2+, Si2+, Cu2+, Ni2+, NH3, Na+, Li+, K+, Ba2+, Zn2+, Mg2+ pH range: 2–8 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 26 ±2 mV/decade at 25°C Electrode resistance: 100 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Calcium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm Ca2+) 30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm Ca2+) Short-Term ISE Soaking Bottle User Manual - GDX-CA

CHF 711.50*
Skip product gallery

Similar Items

Instrumentation Amplifier
The Instrumentation Amplifier can be used to connect a wide variety of measurement equipment to a Vernier interface and electronically collect, store, and analyze the data. Specifications Gain settings: 150, 75, 7.5, 15, 3, and 1.5±5% Linearity: 1% Power: 2.5 mA @ 5 VDC Frequency Response: 0-10 kHz (f3dB) Impedance: 1 MΩ to ground Range settings: 0-20 mV, 0-200 mV, 0-1 V, ±20 mV, ±200 mV, ±1 V What's included Vernier Instrumentation Amplifier User Manual - INA-BTA

CHF 214.00*
Go Direct™ Electrode Amplifier
The Go Direct Electrode Amplifier is a mV and pH amplifier that connects to Vernier electrodes and compatible third-party BNC electrodes. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Units: pH or mV Input range (mV): ±1000 mV Input range (pH): 0 to 14 pH Accuracy with new electrode (mV): ±20 mV Accuracy with new electrode (pH): ±0.2 Connections:Wireless: Bluetooth Wired: USB What's included Go Direct Electrode Amplifier Micro USB Cable User Manual - GDX-EA

CHF 181.40*