Skip to main content Skip to search Skip to main navigation

Go Direct™ ORP Sensor

Product information "Go Direct™ ORP Sensor"

The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It connects via Bluetooth® wireless technology or via USB to your device.

Specifications

  • ORP Electrode
  • Accuracy: ±2% FS
  • Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
  • Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
  • ORP element: 99% pure platinum band sealed on a glass stem
  • Shaft diameter: 12 mm OD
  • Impedance: ~20 kΩ at 25ºC
  • Electrode Amplifier
  • Units: mV
  • Input range: ±1000 mV
  • Connections:Wireless: Bluetooth
  • Wired: USB

What's included

  • Go Direct ORP (includes Go Direct Electrode Amplifier)
  • Micro USB Cable
  • pH storage solution bottle with pH Storage Solution

User Manual - GDX-ORP

Betriebsystem: Android, Chrome, LabQuest 2, Mac OSX, Win, iOS
Bildungsstufe: Diploma/High School, Diploma/ Vocational/ Uni
DataLogger Schnittstellen: LabQuest
Fach: chemistry
Fachbereich: Chemie
Hersteller: Vernier
Schnittstelle: BlueTooth, USB

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Food Chemistry Experiments
Food Chemistry Experiments has 14 experiments that use food as a means to explore crucial chemistry concepts. Students are more likely to engage with science when they see concepts applied to the real world. These experiments use Vernier sensors such as spectrophotometers, temperature probes, and CO2 gas sensors to investigate complex questions involving food. What's IncludedElectronic Version 14 ready-to-use student experiments Electronic access to up-to-date versions of the experiments Instructions for data collection with Vernier Graphical Analysis app with Go Direct sensors. (Does not support data collection with Logger Pro or LabQuest App) Essential instructor information, including teaching tips, suggested answers, and sample data and graphs Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Complete equipment and supplies list A generous site license­—buy one book and duplicate the experiments for your class Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

From CHF 64.80*
pH Sensor
Our general-purpose pH Sensor can be used across disciplines, including chemistry, biology, middle school science, and environmental science. Specifications Range: pH 0–14 Accuracy with new electrode (pH): ±0.2 Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Shaft Diameter: 12 mm OD Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) What's included Vernier pH Sensor pH storage solution pH storage solution bottle User Manual - PH-BTA

CHF 254.80*
Advanced Chemistry with Vernier
Advanced Chemistry with Vernier has 35 advanced chemistry experiments designed for use with Vernier data-collection technology. There are four student alternative versions included for each experiment: computer, LabQuest, calculator, and a generic version that covers all platforms. Experiments are included for the Vernier Temperature Probe, pH Sensor, Conductivity Probe, Drop Counter, Colorimeter, Gas Pressure Sensor, Current Probe, ORP Sensor, and Radiation Monitor. ​Starting with the 2013–2014 school year, the AP Chemistry Course Description recommended labs have been reduced from 22 to 16 and at least six of the 16 experiments should be an inquiry-based model of instruction. Advanced Chemistry with Vernier provides a variety of experiments for the additional 10 non-inquiry experiments. Use it in addition to​ ​Vernier Chemistry Investigations for Use with AP Chemistry​ (APCHEM) ​for a comprehensive set of topics.​

From CHF 83.40*
Vernier Chemistry Investigations for Use with AP* Chemistry - Print and E-Book
This lab book provides AP* Chemistry students with 16 inquiry-based laboratory experiments aligned with the inquiry investigations published by the College Board. Each experiment guides students to investigate key principles of AP Chemistry using electronic sensors to collect important data. User Manual - APCHEM

CHF 120.20*
Go Direct® 300 mAh Replacement Battery
The Go Direct® 300 mAh Replacement Battery is a rechargeable, lithium-polymer unit that comes with a one-year warranty. User Manual - GDX-BAT-300

CHF 22.40*
Go Direct® Charge Station
The Go Direct® Charge Station is the perfect solution for charging your Go Direct Sensors. Each charge station has sixteen charging ports—eight USB and eight wand-style sensor ports. LED lights on the Go Direct sensors will show charging status. The Go Direct Charge Station is also compatible with Go Wireless devices. USB cables not included. User Manual - GDX-CRG-EURO

CHF 232.40*
Electrode Support
Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. What's included Electrode Support User Manual - ESUP

CHF 20.30*
Investigating Chemistry through Inquiry
The Investigating Chemistry through Inquiry lab book contains 25 inquiry-based chemistry investigations. The book is authored by two long-time chemistry teachers, Donald L. Volz and Ray Smola, who have enjoyed using the inquiry method in their own instruction. Each experiment includes a preliminary activity, teacher information, sample researchable questions, and sample data for those researchable questions. If you are new to inquiry-based instruction, the extensive Instructor Sections that are included with each investigation will help guide you through the inquiry-based style of chemistry instruction. Included with Investigating Chemistry through Inquiry  Electronic Version 25 inquiry-based, chemistry investigations Access to up-to-date versions of the experiments Essential teacher information for successful inquiry investigations Suggested researchable questions, sample data, and graphs A generous site license—buy one book and duplicate the labs for your class Word-processing files of the student experiments, so you can edit the files to match your teaching preferences Printed Lab Book When you buy the printed lab book you receive all of the resources listed for the electronic version, plus a printed copy of the book.

From CHF 83.40*
Go Direct® ORP BNC Electrode
Connect the ORP (oxidation-reduction potential) BNC Electrode to the Go Direct® Electrode Amplifier to measure the ability of an aqueous solution to act as an oxidizing or reducing agent. Specifications Accuracy with new electrode (mV): ±20 mV Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Shaft diameter: 12 mm OD Impedance: ~20 kΩ at 25ºC What's included Go Direct ORP BNC Electrode pH storage solution bottle with pH Storage Solution User Manual - GDX-ORP-BNC

CHF 140.60*
Electrode Tip Guard (2 Pack)
Replacement tip guards for Glass-body pH Electrode. User Manual - ETG

CHF 24.40*
Skip product gallery

Similar Items

Go Direct® ORP BNC Electrode
Connect the ORP (oxidation-reduction potential) BNC Electrode to the Go Direct® Electrode Amplifier to measure the ability of an aqueous solution to act as an oxidizing or reducing agent. Specifications Accuracy with new electrode (mV): ±20 mV Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) ORP element: 99% pure platinum band sealed on a glass stem Shaft diameter: 12 mm OD Impedance: ~20 kΩ at 25ºC What's included Go Direct ORP BNC Electrode pH storage solution bottle with pH Storage Solution User Manual - GDX-ORP-BNC

CHF 140.60*
ORP Sensor
The Oxidation-Reduction Potential (ORP) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. Use the ORP Sensor to measure the oxidizing ability of chlorine in swimming pools or to determine when the equivalence point has been reached in an oxidation-reduction reaction. Specifications Type: Sealed, gel-filled, epoxy body, Ag/AgCl reference Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution) Cable: 1 meter coaxial cable with BNC connector Redox potential range: -450 to +1100 mV ORP element: 99% pure platinum band sealed on a glass stem Temperature range: 0-60ºC Probe dimensions: 12 mm OD Impedance: ~20 kΩ at 25ºC What's included ORP Electrode BNC Electrode Amplifier pH storage solution User Manual - ORP-BTA

CHF 285.40*