Specifications

  • Channels
  • Go Direct Weather System has the following measurement channels:
  • Wind Speed
  • Wind Direction
  • Wind Chill
  • Temperature
  • Heat Index
  • Dew Point
  • Relative Humidity
  • Absolute Humidity
  • Station Pressure
  • Barometric Pressure
  • Altitude
  • Specifications
  • Wind speed range: 0–30 m/s
  • Temperature range: –40 to 120°C
  • Temperature accuracy: ±0.2°C
  • Humidity range: 0–100%
  • Humidity accuracy: ±2%
  • Absolute pressure range: 260–1260 mbar
  • Absolute pressure accuracy: ±0.2 mbar
  • Maximum sampling rate: 2 sample/s
  • Maximum wireless range: 30 m (unobstructed)

What's included

  • Go Direct Weather System
  • Go Direct Weather
  • Go Direct Weather Vane
  • Micro USB Cable
  • Go Direct Weather
  • Go Direct Weather
  • Micro USB Cable

User Manual - GDX-WTHR

Betriebsystem: Android, Chrome, LabQuest 2, Mac OSX, Win, iOS
Bildungsstufe: Diploma/High School, Diploma/ Vocational/ Uni, Middle years
DataLogger Schnittstellen: LabQuest
Fach: Biology, Science, Weather, chemistry, geography
Fachbereich: Biologie, Chemie, Natur, Mensch, Gesellschaft - NMG, fächerübergreifend
Hersteller: Vernier
Remote Logging: Supported
Schnittstelle: BlueTooth, USB

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

Climate and Meteorology Experiments - E-Book
Climate and Meteorology Experiments includes 11 experiments with interactive investigations that challenge students to use data-collection technology to explore weather, climate, and other important weather-related topics. User Manual - HSB-CM-E

CHF 44.40*
Go Direct® Weather Vane
The Go Direct Weather Vane accessory is required for Go Direct Weather (not included) to report the direction of the wind. Specifications Dimensions: 6 inches wide x 9 inches tall What's included Go Direct Weather Vane User Manual - WTHR-VANE

CHF 65.20*
Skip product gallery

Similar Items

CO2 Gas Sensor
The CO2 Gas Sensor measures gaseous carbon dioxide in two ranges–0 to 10,000 ppm and 0 to 100,000 ppm. Specifications Response time: 95% of full-scale reading in 120 seconds Warm-up time: 90 seconds Pressure effect: 0.19% of reading/mm of Hg from standard pressure Input potential: 5 V (±0.25V) Gas sampling mode: diffusion Normal operating temperature range: 25°C (±5°C) Operating humidity range: 5–95% (non-condensing) Storage temperature range: –40 to 65°C Measurement Range:Low range: 0 to 10,000 ppm CO2 High range: 0 to 100,000 ppm CO2 Typical Accuracy (at standard pressure, 1 atm):Low range:0 to 1,000 ppm: ±100 ppm 1,000 to 10,000 ppm: ±10% of reading High range:0 to 100,000 ppm: ±20% of reading Resolution:0 to 10,000 ppm CO2: 3ppm 0 to 100,000 ppm CO2: 30ppm What's included Vernier CO2 Gas Sensor 250 mL gas sampling bottle (Nalgene bottle with lid) User Manual - CO2-BTA

CHF 650.30*
Relative Humidity Sensor
The Relative Humidity Sensor can be used for weather studies, monitoring greenhouses, or determining days when static electrical discharges could be a problem. Specifications Range: 0% to 95% Power: 200 µA @ 5 VDC Response Time (time for a 90% change in reading):In still air: 60 minutes (typical) With vigorous air movement: 40 seconds (typical) Typical Resolution: 0.04% RH Humidity Sensor Specifications Specifications for the IH-3602-L Integrated Circuit Humidity Sensor (at 25°C and 5.0 VDC) are given below: Total Accuracy (with saturated salt calibration): ±2% RH Total Accuracy (with standard calibration): ±10% RH Operating Temperature Range: 0 to 85°C Temperature Effect0% RH voltage: ±0.007% RH/°C (negligible) 50% RH voltage: –0.11% RH/°C 95% RH voltage: –0.22% RH/°C What's included Vernier Relative Humidity Sensor User Manual - RH-BTA

CHF 181.40*
Go Direct™ Temperature Sensor
The Go Direct Temperature Probe is a rugged, general-purpose sensor that students can use to monitor temperature. It connects via Bluetooth® wireless technology or via USB to your device. Save money when you purchase the Go Direct Temperature Teacher Pack, which includes 8 Go Direct Temperature Probes and a Go Direct® Charge Station. Specifications Range: –40 to 125°C Handle range: –10 to 45°C Resolution: 0.01°C Accuracy: ±0.25°C Response time (time for 90% of reading): 20 seconds (in water, with stirring) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct Temperature Go Direct Temperature Probe Micro USB Cable Quick-start guide Go Direct Temperature Teacher Pack 8 Go Direct Temperature Probes Charge Station 8 Micro USB Cables Quick-start guide User Manual - GDX-TMP

CHF 161.00*
Anemometer
Use the Anemometer to measure wind speed in a variety of experiments. Hold the sensor in your hand to measure wind speed in dynamic environments or use the accessory rod to position it in front of wind tunnels or fans. Specifications Range: 0.5 m/s – 30 m/s Resolution: 1.2 x 10-2 m/s (LabQuest 2, LabQuest, LabQuest Mini, Go!Link, LabPro) What's included Vernier Anemometer User Manual - ANM-BTA

CHF 254.80*
O2 Gas Sensor
The O2 Gas Sensor can be used to monitor gaseous oxygen levels in a variety of biology and chemistry experiments. The sensor is intended for measuring gaseous, not aqueous, O2 concentration. Specifications Measurement Range: 0–27% (0-270 ppt) Accuracy (@ Standard Pressure 760 mm Hg): +/- 1% O2 Typical Resolution: 0.01% Response Time: 90% of final reading in ~12 seconds Warm-Up Time: Less than 5 seconds Pressure Effect: Directly proportional Vout = Vout (standard) x (P/1013) Pressure range: 0.5 atm to 1.5 atm Output Signal Range: 0.3 to 5 VDC; 2.7 to 3.8 VDC @ 21% O2 Output Impedance: 1 KΩ Input Voltage: 5 VDC +/–0.25 VDC Gas Sampling Mode: Diffusion Normal Operating Temperature Range: 20°C to 30°C Operating Temperature Range: 5 to 40°C (with calibration) Operating Humidity Range: 0 to 95% RH Storage Temperature Range: –20 to +60°C Dimensions: Sensor Tube: 45 mm length, 28 mm OD Total length: 135 mm What's included Vernier O2 Gas Sensor 250 mL gas sampling bottle User Manual - O2-BTA

CHF 489.20*
O2 Gas Sensor
The Go Direct O2 Gas Sensor measures gaseous oxygen concentration levels and air temperature. It is useful for a variety of biology and physiology experiments. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Oxygen SensorCell type: Electrochemical cell Range: 0–100% (0–1000 ppt) O2 Accuracy (at standard pressure 760 mm Hg): ±1% O2 Resolution: 0.01% O2 Temperature SensorType: Thermistor Accuracy: ±0.5°C Resolution: 0.1°C DimensionsSensor tube length: 38 mm Sensor tube diameter: 28 mm Total length: 155 mm ConnectionsWireless: Bluetooth Wired: USB What's included Go Direct® O2 Gas Sensor Micro USB Cable 250 mL Nalgene Bottle w/Lid User Manual - GDX-O2

CHF 487.20*