Skip to main content Skip to search Skip to main navigation

Nitrate Ion-Selective Electrode

Product information "Nitrate Ion-Selective Electrode"

The Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples.

Specifications

  • Range (concentration): 1 to 14,000 mg/L (or ppm)
  • Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L)
  • Interfering ions: CIO4–, I–, ClO3–, CN–, BF4–
  • pH range: 2–11 (no pH compensation)
  • Temperature range: 0–40°C (no temperature compensation)
  • Electrode slope: -55 ±3 mV/decade at 25°C
  • Electrode resistance: 1–4 MΩ
  • Immersion: 2.8 cm
  • Electrode length: 155 mm
  • Body diameter: 12 mm
  • Cap diameter: 16 mm
  • Cable length: 100 cm

What's included

  • Vernier Nitrate Ion-Selective Electrode
  • 30 mL bottle of Nitrate Low Standard (1 mg/L or 1 ppm NO3–)
  • 30 mL bottle of Nitrate High Standard (100 mg/L or 100 ppm NO3–)
  • Short-term ISE soaking bottle

User Manual - NO3-BTA

Bildungsstufe: Diploma/ Vocational/ Uni
Fach: Biology, chemistry

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

ISE Nitrate High Standard
The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes. User Manual - NO3-HST

CHF 59.10*
ISE Nitrate Replacement Module
This module replaces the PVC electrode in the Nitrate ISE. User Manual - NO3-MOD

CHF 193.20*
Electrode Support
Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. What's included Electrode Support User Manual - ESUP

CHF 20.30*
ISE Nitrate Low Standard
The High and Low ISE standards are used to calibrate Nitrate Ion-Selective Electrodes. User Manual - NO3-LST

CHF 59.10*
Water Quality with Vernier
Water Quality with Vernier has 18 water quality tests, including pH, total dissolved solids, dissolved oxygen, BOD, flow rate, turbidity, nitrates, and phosphates. All nine tests in the Water Quality Index (WQI) are supported. A comprehensive introduction is included for each test, providing important background information for the students. The printed version includes access to the electronic edition online.  

From CHF 83.40*
Skip product gallery

Similar Items

Calcium Ion-Selective Electrode
The Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of Calcium (Ca2+) in aqueous samples. Specifications Range (concentration): 1 to 40,000 mg/L (or ppm) Reproducibility (precision): ± 10% of full scale (calibrated 10 to 1000 mg) Interfering Ions: Pb2+, Hg2+, Si2+, Fe2+, Cu2+, Ni2+, NH3, Na+, Tris+, Li+, K+, Ba2+, Zn2+, Mg2+ pH Range (concentration): 2–8 (no pH compensation) Temperature range: 0-40°C (no temperature compensation) Electrode Slope: +26 mV/decade at 25°C Electrode Resistance: 100 MΩ Immersion: 2.8 cm (1.1 in) Electrode length 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Calcium Ion-Selective Electrode 30 mL bottle of Calcium Low Standard (10 mg/L or 10 ppm Ca2+) 30 mL bottle of Calcium High Standard (1000 mg/L or 1000 ppm Ca2+) Short-term ISE soaking bottle User Manual - CA-BTA

CHF 713.50*
Go Direct® Ammonium Ion-Selective Electrode
The Go Direct Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of ammonium (NH4+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 18,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: K+, Li+, Na+, Cs+, Mg2+, Ca2+, Sr2+, Ba2+ pH range: 2–7 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Ammonium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (100 mg/L or 100 ppm NH4+ as N) 30 mL bottle of Low Standard solution with SDS (1 mg/L or 1 ppm NH4+ as N) Short-Term ISE Soaking Bottle User Manual - GDX-NH4

CHF 670.70*
Nitrate Ion-Selective Electrode
Connect the Go Direct® Nitrate Ion-Selective Electrode BNC to our Go Direct® Ion-Selective Electrode Amplifier to measure the potential (mV) and calculate the concentration of nitrate (NO3-) ions in aqueous samples. Specifications Range (mV):Go Direct® Ion-Selective Electrode Amplifier: -1000 mV to +1000 mV Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±30mV Interfering ions: ClO4–, I–, ClO3–, F– pH range: 2.5–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 0.1 to 5 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) What's included Go Direct Nitrate Ion-Selective Electrode with BNC terminated end, packed with a storage bottle 30 mL bottle of High Standard solution with SDS (1000 mg/L NO3–) 30 mL bottle of Low Standard solution with SDS (10 mg/L NO3–) Short-Term ISE Soaking Bottle User Manual - GDX-NO3-BNC

CHF 548.40*