Calcium Ion-Selective Electrode

Product information "Calcium Ion-Selective Electrode"

The Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of Calcium (Ca2+) in aqueous samples.

Specifications

  • Range (concentration): 1 to 40,000 mg/L (or ppm)
  • Reproducibility (precision): ± 10% of full scale (calibrated 10 to 1000 mg)
  • Interfering Ions: Pb2+, Hg2+, Si2+, Fe2+, Cu2+, Ni2+, NH3, Na+, Tris+, Li+, K+, Ba2+, Zn2+, Mg2+
  • pH Range (concentration): 2–8 (no pH compensation)
  • Temperature range: 0-40°C (no temperature compensation)
  • Electrode Slope: +26 mV/decade at 25°C
  • Electrode Resistance: 100 MΩ
  • Immersion: 2.8 cm (1.1 in)
  • Electrode length 155 mm
  • Body diameter: 12 mm
  • Cap diameter: 16 mm
  • Cable length: 100 cm

What's included

  • Vernier Calcium Ion-Selective Electrode
  • 30 mL bottle of Calcium Low Standard (10 mg/L or 10 ppm Ca2+)
  • 30 mL bottle of Calcium High Standard (1000 mg/L or 1000 ppm Ca2+)
  • Short-term ISE soaking bottle

User Manual - CA-BTA

Bildungsstufe: Diploma/High School, Diploma/ Vocational/ Uni
DataLogger Schnittstellen: LabPro, LabQuest
Fach: Biology, Water Quality, chemistry
Fachbereich: Biologie, Chemie

0 of 0 reviews

Average rating of 0 out of 5 stars

Leave a review!

Share your experiences with other customers.


Skip product gallery

Accessory Items

pH Buffer Capsules Kit
The pH Buffer Capsules Kit is a convenient set of three vials containing capsules to make pH 4, pH 7, and pH 10 buffer standards for calibrating pH sensors. Included with the set is one vial of Hydrion Color Key Buffer Preservative. What's included (10) pH 4 – Orange (10) pH 7 – Green (10) pH 10 – Blue Color Key Buffer Preservative Solution preparation instructions Safety Data Sheets User Manual - PH-BUFCAP

CHF 79.50*
ISE Calcium Low Standard
The High and Low ISE standards are used to calibrate our Calcium Ion-Selective Electrodes. User Manual - CA-LST

CHF 59.10*
Water Quality with Vernier
Water Quality with Vernier has 18 water quality tests, including pH, total dissolved solids, dissolved oxygen, BOD, flow rate, turbidity, nitrates, and phosphates. All nine tests in the Water Quality Index (WQI) are supported. A comprehensive introduction is included for each test, providing important background information for the students. The printed version includes access to the electronic edition online.  

From CHF 83.40*
Electrode Support
Our Electrode Support is a great complement to the Vernier Stir Station, as well as a perfect holder for many sensors. It is built to connect to all standard ring-stand posts; its large-handled locking nut keeps your sensors firmly in place. The larger opening (13 mm in diameter) is perfect for our pH, ISE, Conductivity and ORP sensors. The smaller opening (5 mm) is designed to hold our Stainless Steel Temperature Probe or the Vernier Go!Temp. What's included Electrode Support User Manual - ESUP

CHF 20.30*
ISE Calcium High Standard
The High and Low ISE standards are used to calibrate our Calcium Ion-Selective Electrodes. User Manual - CA-HST

CHF 59.10*
ISE Calcium Replacement Module
This module replaces the electrode membrane. Simply unscrew the old one and screw on the new one. The membrane of a Calcium ISE electrode has a limited life span of one to two years, regardless of frequency of use. Do not order it until you need it, as it will age even when not in use. User Manual - CA-MOD

CHF 193.20*
Skip product gallery

Similar Items

Potassium Ion-Selective Electrode
The Potassium Ion-Selective Electrode can be used to measure the concentration of potassium (K+) ions in aqueous solutions. Specifications Range (concentration): 1 to 39,000 mg/L (or ppm) Reproducibility (precision): ±11% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Cs+, NH4+, H+, Ag+, Li+, Na+ pH range: 2–12 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–10 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Potassium Ion-Selective Electrode 30 mL bottle of High Standard Standard (1000 mg/L or 1000 ppm K+) 30 mL bottle of Low Standard Standard (10 mg/L or 10 ppm K+) ISE soaking bottle (empty bottle with insertion cap) User Manual - K-BTA

CHF 705.30*
Ammonium Ion-Selective Electrode
The Ammonium Ion-Selective Electrode (ISE) can be used to measure the concentration of Ammonium (NH4+) in aqueous samples. Specifications Range (concentration): 1 to 18,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: K+, Li+, Na+, Cs+, Mg3+, Ca2+, Sr2+, Ba2+ pH range: 4–7.5 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: +56 ±4 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Ammonium Ion-Selective Electrode 30 mL bottle of Ammonium Low Standard (1 mg/L or 1 ppm NH4+ as N) 30 mL bottle of Ammonium High Standard (100 mg/L or 100 ppm NH4+ as N) Short-term ISE soaking bottle User Manual - NH4-BTA

CHF 672.70*
Nitrate Ion-Selective Electrode
The Nitrate Ion-Selective Electrode (ISE) can be used to measure the concentration of Nitrate (NO3-) in aqueous samples. Specifications Range (concentration): 1 to 14,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 1 to 100 mg/L) Interfering ions: CIO4–, I–, ClO3–, CN–, BF4– pH range: 2–11 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: -55 ±3 mV/decade at 25°C Electrode resistance: 1–4 MΩ Immersion: 2.8 cm Electrode length: 155 mm Body diameter: 12 mm Cap diameter: 16 mm Cable length: 100 cm What's included Vernier Nitrate Ion-Selective Electrode 30 mL bottle of Nitrate Low Standard (1 mg/L or 1 ppm NO3–) 30 mL bottle of Nitrate High Standard (100 mg/L or 100 ppm NO3–) Short-term ISE soaking bottle User Manual - NO3-BTA

CHF 713.50*
Go Direct® Calcium Ion-Selective Electrode
The Go Direct Calcium Ion-Selective Electrode (ISE) can be used to measure the concentration of calcium (Ca2+) in aqueous samples. It connects via Bluetooth® wireless technology or via USB to your device. Specifications Range (mV): ±1000 mV Range (concentration): 1 to 40,000 mg/L (or ppm) Accuracy: ±10% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: Pb2+, Hg2+, Si2+, Cu2+, Ni2+, NH3, Na+, Li+, K+, Ba2+, Zn2+, Mg2+ pH range: 2–8 (no pH compensation) Temperature range: 0–40°C (no temperature compensation) Electrode slope: 26 ±2 mV/decade at 25°C Electrode resistance: 100 MΩ Minimum sample size: must be submerged 2.8 cm (1.1 in) Connections:Wireless: Bluetooth Wired: USB What's included Go Direct ISE Amplifier attached to a Go Direct Calcium Ion-Selective Electrode BNC Micro USB cable 30 mL bottle of High Standard solution with SDS (1000 mg/L or 1000 ppm Ca2+) 30 mL bottle of Low Standard solution with SDS (10 mg/L or 10 ppm Ca2+) Short-Term ISE Soaking Bottle User Manual - GDX-CA

CHF 711.50*
Chloride Ion-Selective Electrode
The Chloride Ion-Selective Electrode (ISE) is used to measure the concentration of Chloride (Cl-) in aqueous samples. Specifications Range (concentration): 1 to 35,000 mg/L (or ppm) Reproducibility (precision): ±10% of full scale (calibrated 10 to 1000 mg/L) Interfering ions: CN–, Br–, I–, OH–, S2–, NH3 pH range: 2–12 (no pH compensation) Temperature range: 0–80°C (no temperature compensation) Electrode slope: –56 ±3 mV/decade at 25°C Electrode resistance: 1 to 5 MΩ Immersion: 2.8 cm Electrode length: 125 mm Body diameter: 12 mm Cable length: 100 cm What's included Vernier Chloride Ion-Selective Electrode 30 mL bottle of Chloride Low Standard (10 mg/L or 10 ppm Cl–) 30 mL bottle of Chloride High Standard (1000 mg/L or 1000 ppm Cl–) Short-term ISE soaking bottle Polishing Strips User Manual - CL-BTA

CHF 672.70*